To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Enterprise SCADA Server

Showing 100

Analog field rawval should be replicated to non-owning sites

Client has observed that the ANALOG "rawval" field is not replicating to non-owning sites; and they expect this value to be replicated. Anything else relevant to this feature? There is an optional feature called the "Raw Data Enhancement" RAW_ENAB...
Guest over 1 year ago in Enterprise SCADA Server / Replication 2 Waiting for information

How to install applications from MS store in OT zone

Some support applications are only available in the MS Store, but the LTSC versions of the OS do not come with the MS store installed, nor do we want to install it.

MoC Extensions Disabled by Default

As a system integrator I would prefer to see MoC extensions disabled by default, to be enabled if needed, in order to remove this from the required lists of tasks to be executed for a system installation having MoC.
Tyson Burr 11 months ago in Enterprise SCADA Server 0

Enhance NMC to be more descriptive as to what resource the "FreeSpace" monitoring/alarm is for

Has this functionality been delivered before?: It is configurable today, but must be done on every machine individually. In large installs, this is a large effort. Links OGPM: http://tcjira.aveva.com/browse/OGPM-3091
Tyson Burr almost 2 years ago in Enterprise SCADA Server / Administration / Installation / Architecture 0 Future consideration

Make LogViewer File->Open default to folder of currently open log file

Big Picture User Experience Make LogViewer File->Open default to folder of currently open log file Detailed Description Currently, when a user opens a log file, and then attempts to open another log file, the file->open dialog box always def...
Jake Hawkes 12 months ago in Enterprise SCADA Server 0 Reviewing

Enhance Re-alarming application for any alarm severity

Big Picture User Experience Enable Re-Alarming application to re-alarm alarms of any severity that were acknowledged by SCADA controller Detailed Description Background Re-Alarming application designed to re-annunciate alarms that are previously w...
Guest about 2 years ago in Enterprise SCADA Server / Alarms 1 Future consideration

Update SNMP protocol to support v3

Big Picture User Experience Support v3 of the SNMP protocol Detailed Description TBD: any particular SNMP v3 features?
Randy Kostiuk about 2 years ago in Enterprise SCADA Server / Protocols and Commlines 6 Future consideration

ADE find/replace case sensitivity

Summary In 7.6, the Find was insensitive but the Replace was sensitive. This resulted in fewer rows being modified than what was found in the Find. In other words, it was a hidden defect. Making Find and Replace consistent was important to ensure ...
Josie Liu about 2 years ago in Enterprise SCADA Server / ADE / PnT / MoC 2 Will not implement

[Test & DOC] Ability to configure datapump to pull data from an untrusted domain

Big Picture User Experience Officially test and document the feature added to datapump in OASyS 7.6R4 to allow pulling from an untrusted, lower security zone. Detailed Description Customer wants to datapump data from an untrusted domain into a tru...
Tyson Burr about 2 years ago in Enterprise SCADA Server / Administration / Installation / Datapump / Documentation 0 Future consideration

Re-think, and re-design the PI interface

Background The current PI-OASyS interface was designed for the 7.4 version of OASyS. This interface will remain supported for all versions it was released with. It uses OSIsoft APIs/SDKs which are practically EOL, and are certainly no longer evolv...
Jake Hawkes over 5 years ago in Enterprise SCADA Server / OSIsoft PI 0 Planned