To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Plant SCADA

Showing 106 of 567

Edit Equipment types with a table tool like Excel

when it is needed to update a lot (not all) of variable and trend definitions for example Historian = true within an equipment type. Browsing to the item, opening the definition, add the field and set the value to true will take a lot of time. Whe...
Guest almost 2 years ago in Plant SCADA / Equipment 3 Unlikely to implement

Add ability to lock guidelines in Graphics Builder (so they dont change when you accidentally click them)

The problem is: in the graphics builder the guidelines can be clicked or dragged using the mouse, and then they change! Whilst dragging is quite a conscious action, clicking something is easily done accidentally. You are not warned that you clicke...
Guest almost 3 years ago in Plant SCADA / Graphics / Visualization 1 Unlikely to implement

Enlarge the tables in the kernel

For instance the CSAToPSI.Subs, it starts with the cluster name, then the tag, which can 79 characters. You can only see 29 characters. Also in a kernel dump the length is limited. Also sorting on different colums would be helpfull.
Guest over 1 year ago in Plant SCADA / Kernel & Diagnostics 0

Process Analyst connects to WW Historian

Process Analyst can connect to Citect Historian ,ref to picture. Then is should be possible to connect to Aveva Historian alias WW Historian.
Guest over 4 years ago in Plant SCADA / Alarms 0 In Roadmap

Process Analyst in dark mode

A complete dark Mode of the Process Analyst is not possible. Some parts of the PA can’t be changed. There are no properties to change the background and foreground color of the toolbar and object view.
Guest over 1 year ago in Plant SCADA / Alarms 2 Future Consideration

Citect Studio Login

Instead of an error message when trying to start studio as a user who is not a member of the "SCADA.ConfigUsers" local group. Why not present a login form, similar to Deployment Server? This would reduce frustration, and also many times users thin...
Guest about 1 month ago in Plant SCADA / Development Tools 0 Future Consideration

Fontsize ciode form functions

The posibility to change the fontsize, font used in the cicode form functions.
Guest 10 months ago in Plant SCADA / Graphics / Visualization 0

Logging Citect alarm in Wonderware Historian

Wondering what the plans are for getting the Citect alarm properties in order when logging into AVEVA History. Today if you log alarms from Citect to the Historian you only get AlarmTag, AlarmName and Category as useful data. All other properti...
Guest over 2 years ago in Plant SCADA / Alarms 0 In Roadmap

Upgrade the MAXIMUM LENGHT for STRING and CITECT.INI Parameters over 254 characters !

As discussed in TN000028481 , the MAXIMUM LENGHT for STRING and CITECT.INI Parameters is 254 characters ! This cause many problems inside CICODE SCRIPTS (this limit is too strong in modern world!) and in [Event] parts of citect.ini (you must reduc...
Guest over 1 year ago in Plant SCADA / Development Tools 0

Add 64-bit INT to Modbus Driver

Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Guest over 1 year ago in Plant SCADA / Drivers / Protocols 0