To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 831 of 831

Reuse old ideas

Citect already had a forum for ideas a few years ago. It was at http://www.citect.schneider-electric.com/forum/forumdisplay.php?f=399 Maybe it's possible to import those ideas, at least the better ones that are not implemented yet.
Guest almost 6 years ago in Plant SCADA / Other 3 Unlikely to implement

Point Conditioning application should support point conditioning updates from multi threaded callers

[customer] experienced lock contention issues when updating point conditioning inputs from within ACE code. Investigation into this issue in support case https://gcsservicecloudutils.azurewebsites.net/casedetails?casenumber=960273706 and R&D I...
Andrew Potkins about 1 year ago in Enterprise SCADA Server / Realtime 0

Do not reload windows/pages on login/logout

Have the possibility to configure citect to not reload windows/pages when a user is login or logout.
Geoffrey Estrade 6 months ago in Plant SCADA / Graphics / Visualization 0 Submitted

Configure a commanded status point to alarm in abnormal state

Customer desires the ability to configure status points so that an alarm is generated when a status point is commanded to (and enters) an abnormal state. Attaching use case as described by customer in SC 960445947
Guest over 1 year ago in Enterprise SCADA Server 1

Repeatedly open the page, OMI's data will come out directly, do not come out first#

When using the OMI of 2023R2SP1P02, the customer found that even if the page is repeatedly opened, the data refresh of the OMI still lags behind, and when the screen is opened, the # sign appears first, followed by the data. The customer does not ...
yongyun chen 6 months ago in Application Server / OMI Apps 1 Will not implement

Dnaswana with DALPrompter

Big Picture User Experience Enable SCADA Administrator to use a centralized server to monitor and troubleshoot communications on multiple systems. Detailed Description To enhance security and reduce server resources, customers typically install mo...
Vitali Unke about 2 years ago in Enterprise SCADA Server / Architecture / Omnicomm / Security and DMZ 0 Reviewing

The OPC UA driver should be able to read Tags, Alarms and Events

The OPC UA driver should be able to read Tags, Alarms and Events from other Scadas (iFix, Cimplicity, WinCC, Etc)
Guest about 2 years ago in Device Integration 1

Improve Gr Access toolkit

Enhance the Deployment function by adding a parameter that allows deployments to be performed without enabling ‘Preserve Runtime Changes". Currently, it is always enabled with no option to disable it.
Kim Larsen 6 months ago in Application Server / GR 0

Undo for redefined values for UDT data type

We can redefine/override values on some level of UDT template structure (MinEU, MaxEU, Alarm Group etc.) But once it is done, there is no way to undo it, and ensure that the UDT type inherits the value again from its ancestor data type (as if it w...
Pavel Prusa 6 months ago in InTouch HMI 0 Planned

S7TCP driver does not talk to PLCSIM Advanced

Not sure why my previous submission was deleted, so I send again. S7TCP driver needs update to resolve the issue with the communication with Siemens PLCSIM Advanced simulator while other SCADA software can easily talk to it.
Guest over 2 years ago in Device Integration 1