To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 776 of 776

Quality over time

Currently, we cannot have multiple quality events for a given lot (example) in the unfinalized period. This is very limiting, as in reality, projects do have multiple samples for a given lot, and the need for quality over time. The product today d...
Priyanka VINAYCHANDER about 5 years ago in Production Management (AMPLA MES) 0 Planned

Mitsubishi FX5U PLC driver for Plant SCADA

MELSECQ protocol can be used to communicate with FX5U, but the addressing system is different. MELSECQ expects Hexadecimal addressing while FX5U expects Octal addressing system.
Jiri Rysavik over 1 year ago in Device Integration 0

How to communicate between Plant SCADA and OMRON PLC NJ series

Among Korean Plant SCADA users, there are often users who use Omron NJ series PLC. They express great inconvenience and dissatisfaction about the lack of communication between Plant SCADA and Omron NJ PLC. The method of changing the address of KB0...
Guest over 1 year ago in Device Integration 0

Column/row-wise adding or deleting of models

When creating a Composite Model, allow models to be selected or deselected by row or column. Currently possible only individually or all together.
Geoff Lewis over 2 years ago in APC / Model Identification 0 Evaluating

Define Controller Watchdog Tags

allow them to be selected from a List, avoid the potential for typos and other errors.
Geoff Lewis over 2 years ago in APC / Controller Configuration 0 Evaluating

Define DCS Readback and DCS Status

When defining these tags in a controller, allow them to be selected from a list of all Input Tags, with possibility to apply a filter to limit the size of the presented list. Currently we have to enter the text directly with all kinds of possibili...
Geoff Lewis over 2 years ago in APC / Controller Configuration 0 Evaluating

Convert Raw Tag to Custom

Currently it is possible to convert a Custom Tag to Raw Tag, but not vice versa. This would be v helpful when migrating controllers.
Geoff Lewis over 2 years ago in APC / General 0 Evaluating

Use TagInfoEx() to check whether an alarm exists

If you have an equipment type with an item and this creates a variable tag and an alarmtag you could use the TagInfoEx() function to check whether this item has an alarm defined. Let me give an example: Equipment:Motors.M1 Item:Run Variable Tag Na...
Guest over 2 years ago in Plant SCADA / Equipment 0

Create new Trend Type that hooks into Variable Tag Subscriptions

Traditional periodic Trend type makes the end user set a very small sample time such that no sample is missed. This is a complete mis-match between what is happening at the tag level. I propose a new Trend type that hooks into the Tag Subscription...
Guest over 5 years ago in Plant SCADA / Alarms 3 Unlikely to implement

Make LogViewer File->Open default to folder of currently open log file

Big Picture User Experience Make LogViewer File->Open default to folder of currently open log file Detailed Description Currently, when a user opens a log file, and then attempts to open another log file, the file->open dialog box always def...
Jake Hawkes over 1 year ago in Enterprise SCADA Server 0 Reviewing