To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 774 of 774

KPI targets based on calendar loopkup should look at target for each sub period

[Problem Summary]Merhnoosh have found an issue with calendar items used as a target for Metrics KPIs. When you have a calendar item bound to a period (ie daily target), and is used as a target for a metrics KPI, Ampla doesn’t calculate the correct...
Nina NICHOLLS over 5 years ago in Production Management (AMPLA MES) 0 Planned

Add Break and Continue statements to Cicode

Break and continue are 2 statements that are very common in programming languages. Break is used to jump out of a loop skipping the code below it and continue skips the remaining statements in the body of the loop and performs the next iteration o...
Liron Hallak over 5 years ago in Plant SCADA / Development Tools 0 Future Consideration

Find, Search and replace in genies which are displayed with DspSym()

If you have created a genie which you want to use in runtime you have to set the 'I want to use this Genie with the Cicode function DspSym' to TRUE. It's then not possible to search and replace something in this genie. Search for instance in the E...
Guest almost 4 years ago in Plant SCADA / Development Tools / Graphics / Visualization 0

"Single Record" view of alarms

Combine ".Set", ".Clear" and ".Ack" records into a single record for simpler reporting. Possible today with SQL, but complicated. Better to have a targeted "extension table" for this use case. Also needed for REST Would be useful for the current A...
Elliott Middleton almost 2 years ago in Historian & Client / Alarm & Event 2 Submitted

Cluster field when adding a pen to the process analyst should be a pull-down menu

When adding a pen to the process analyst, it would be great if the cluster field was a pull down with the available clusters listed from the project. With multi-cluster projects, this would help filter out the trend tag lists, as the end-user does...
Guest over 5 years ago in Plant SCADA / Alarms 0 Future Consideration

Allow customers to latch alarms

Here is one problem customers are encountering with our alarming philosophy, where we replace the existing alarm with a new one with the current alarm state: Because the alarm for exceeding hi-hi isn’t latched, operators are missing that MAOP was ...
Collin Heggerud over 5 years ago in Enterprise SCADA Server / Alarms / Control Room Management 0

Collect doesn't collect current real-time value at top of hour

Customer Requirement Our customers require the ability to maintain complete Timeseries historical trends (collect samples), including timestamped samples polled after a PLC communication loss (outage could be for several hours/days). The customer ...
Guest almost 4 years ago in Enterprise SCADA Server / Historical / Realtime 2 Waiting for information

Alternate timeseries hourly averaging algorithm

Enhancement request to either allow integrators to modify timeseries averaging algorithm or provide hooks to allow integrator to modify the operation. We implemented an alternative timeseries averaging algorithm on many installations. Prior to bin...
Guest almost 4 years ago in Enterprise SCADA Server / Historical / Realtime API/SDK 1

Expansion of point description field string length

SE PA WWW previously modified database schema and structure now with binary release modifications tot he database structure are limited. Support for modifying existing types including changing string length is not supported. SE PA WWW typically...
Guest almost 4 years ago in Enterprise SCADA Server / Realtime Schema 3 Will not implement

Support extensions in ISM with > 1024 characters

Can we add an item onto the backlog to support extensions in ISM with > 1024 characters. Since we are using ISM for recording certain configuration, an example situation is a JSON template which may easily be larger than this, which will make a...
Andy Davidson almost 4 years ago in Information Standards Manager 0