To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 545

Support OMI web client as a PWA

Allow OMI web client to be installed as a Progressive Web Application (PWA)
Ernst van Wyk 3 months ago in Application Server & OMI / OMI web runtime 0 Planned

Shift + Scroll to Horizontally Scroll in Graphic Editor

Shift + Scroll is a common application hotkey combo to horizontally scroll. It would be valuable if this was added to the graphic editor as there is currently no way to horizontally scroll other than dragging the horizontal scroll bar.
Andrew Jacobsson 3 months ago in Application Server & OMI / Graphic Editor 1

Setting Symbol Owning Object Property with Expression

Currently there are two ways to set an owning object dynamically via any expression or reference that resolves to a string: ShowGraphic/ShowContent and most recently, EmbedContent, which allows the owning object to be set as a string of the respe...
Andrew Jacobsson 3 months ago in Application Server & OMI / Graphic Editor 0

S7TCP-driver to support firmware 3

New Siemens S7-1500 controllers have firmware 3. The S7TCP doesn’t support this firmware version
Guest 12 months ago in Device Integration 0

Acknowledge Alarms in an area with Area Attribute

No description provided
Danny Power 16 days ago in Application Server & OMI 1

IDE Object editor - Ability to check in and deploy an object while keeping its editor tab open

When troubleshooting objects scripts, one frequently needs to go through this workflow: check out + open an object/template in the IDE modify scripts/attributes close the editor tab (required to check it in) check it in (for changes to propagate t...
Rob Budak 3 months ago in Application Server & OMI / IDE 0

Sort or filter S7TCP Tag Import

When using the Import Tags tool from the I/O Devices activity menu it lists all the available variables from the source PLC. It's not possible to sort or filter the list.
Guest about 1 month ago in Device Integration 0
100 VOTE

BACNET: Addressing objects via ObjectName

We have several requests for accessing BACNET objects via their "ObjectName", rather than their HW address ie: AI.1.PresentValue. There are 2 issues with the current way of addressing: Makes it difficult to make equipment Some PLC’s (ie Wago) shif...
Guest over 4 years ago in Device Integration 1

IDE indicator for nearing the per-object Attribute limit

The MES OCO User Guide mentions this important note: An entity can have a maximum of 50 jobs. However, there is a limitation within System Platform that an object can have a maximum of 5000 attributes. Hitting this limit is quite feasible when usi...
Rob Budak about 2 months ago in Application Server & OMI / IDE 1

OPCUA Variable Import limited to 79 characters

When you import Variable Tags from an OPCUA Server the tag names are truncated to 79 characters, this is sometime not enough. Duplicate tagnames are not allowed. You have to manually adjust all the names. For instance when you connect to a Plant S...
Guest about 1 year ago in Plant SCADA / Drivers / Protocols 1