Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Load New BLTs without Restart or Failover

No description provided
Guest almost 3 years ago in Enterprise SCADA Server 0 Reviewing

Add customer test scripts to automated testing

Multiple customers have offered to share their test scripts with us to improve our ability to test usage that better matches customer environments.
Jake Hawkes almost 3 years ago in Enterprise SCADA Server 0

Address nuisance error log messages related to the Trend BLT

Detailed Description Request that the Recordset open error be moved to ALWAYS as it does provide insight into an issue with trending a point 2022-05-16 12:18:36.744 [TID=0x299c] WARNING: Trend: numCollects: Recordset open (execute) failed [-214721...
Serge LeBlanc almost 3 years ago in Enterprise SCADA Server / Administration / Installation 1 Future consideration

HCAP Ping Utility

A command line utility to test HCAP/HCAL connectivity.
Elliott Middleton almost 3 years ago in Historian & Client / Install and Upgrade / Maintenance and Management 0 Submitted

Request disabling NetBios be validated

This request created created from a Pembins 2018 SP3 inquiry but I believe it has been agreed to only be considered for supported versions or future release. Previous IMS from ConEd - 2178824 was closed stating, "noting they need to validate the c...
Serge LeBlanc almost 3 years ago in Enterprise SCADA Server / Administration / Installation / Architecture / Security and DMZ 1 Reviewing

Adding "Remote" parameter to the "FilterFlexTag" BLT

This is related to IMS 2573721 The Albuquerque Water Utility is requesting that remote filtering be added to the FlexTag Summary display as this feature exists for tag summary display and most of the time used to filter flextags of a particular Re...
Guest almost 3 years ago in Enterprise SCADA Server / Control Room Management / Other API/SDK / Realtime 1 Future consideration

Disable read from certain tags in knx driver

The driver will today read everything after a certain time if not otherwise refreshed. Some tags are not readable and event based only, to avoid uneccesary traffic there should be a possibility to disable read, similar to option for setpoints.
Dan Helgeland about 3 years ago in Device Integration 0

Enhance Device Rollup to support subdevices from multiple datasets

Big Picture User Experience Enhance device rollup from subdevices (telemetered and device object) that belong to datasets that differ from the parent device (top-level device) object dataset. Background With large systems it is now very common to ...
Guest about 3 years ago in Enterprise SCADA Server / Alarms / Control Room Management 0 Reviewing

GroupArea in the area table only contains the first 20 groups

Do we actually have a limit of 20 groups per area? Some testing has shown that one can add more then 20 groups into an area. The GroupAreaJoin table populates all of them correctly however the "group[0-19].name” array-field in the area table only ...
Bradley Tomanik about 3 years ago in Enterprise SCADA Server / Administration / Installation / Realtime 1 Already exists

DNP3 - "Listening mode"

The current version of DNPR or DNP3 driver always want's to initiate the start of communication with the device. There are some devices that work in an opposite direction (i.e. Metasphere DNP3 data loggers https://www.metasphere.co.uk/products/poi...
Ales B about 6 years ago in Device Integration 0