To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Alarm Event Type is Application Write for InTouch tags, but is expecting it to be User Write

User has standalone intouch application with primary alarm provider and logger node and RDS node. When looking at events specifically (such as changing alarm setpoint) the operator logged in does not reflect properly in alarm/event viewer. For exa...
Jake Hawkes 3 days ago in Historian & Client / Alarm & Event 0 Submitted

[PlantSCADA] Ability to Historize other Data Type (like INT/REAL)

4.1 Be able to Historize other Data Type (like INT/REAL) of tag variables , not just the Digital/String Data Types Looks like this is done by choice or some other reasons, e.g. name clashes. The Connector code currently explicitly filters out vari...
Marcell Marjee 6 months ago in Historian & Client / Data Acquisition 0 In Roadmap

Provide a model for Remaining Useful Lifetime

As we do asset condition and reliability monitoring, we want to understand, how long an equipment might run given the current condition monitoring and process data and want to provide information for a potential maintenance window.
Hans-Otto Weinhold about 2 months ago in Advanced Analytics 0 Needs review

Ability to choose timezone of dates and times in UI

When investigating something like an anomaly score for a plant located in a different timezone than the user, it can be confusing to try to line up anomaly spikes with what is happening in the plant. It would be nice to be able to configure a diff...
Jessica Rammo about 1 year ago in Advanced Analytics 0 Needs review

[PlantSCADA] Better support for tag config changes on PlantSCADA end

4.3 Changes to Plant SCADA configuration Where there are changes from the PlantSCADA side, a restart of the connector is required however there are many cases of where the users forget to do this. A reminder message may help. Looks like this is do...
Marcell Marjee 6 months ago in Historian & Client / Data Acquisition 0 In Roadmap

[PlantSCADA] Fault tolerance to errors on the PlantSCADA side

2.0 Fault Tolerance of the connector to SCADA misconfiguration If there is a misconfiguration on the SCADA side, for example after the system is running, then it can lead to the ctapi connection being dropped and no logs for all tags, and not just...
Marcell Marjee 6 months ago in Historian & Client / Data Acquisition 1 In Roadmap

[PlantSCADA] Make connector activity visible in PlantSCADA UI

The main issue is that if you stop Plant SCADA while a backfilling operation is ongoing but the Connector is still working, then we get the issue that data is written on wrong blocks into historian. To successfully complete the backfill operation,...
Mats-Peter Cansund 6 months ago in Historian & Client / Data Acquisition 3 In Roadmap

Show timestamps for property value symbol on a monitor

Property Value Symbol in a monitor should provide also timestamp as available field as the user would like to know of when a specific value got updated. Right now, selecting the timestamp field is not an option.
Hans-Otto Weinhold 4 months ago in Advanced Analytics 0 Needs review

Better Event Support for external / inbound MES Events or PI Event Frames

Currently, AVEVA Advanced Analytics provides a very "simple" event schema. However, when linking events from MES (AVEVA MES or ProLeiT MES) or PI, they can contain much more complex structures. This should be as well supported in AVEVA Advanced An...
Hans-Otto Weinhold 4 months ago in Advanced Analytics 0 Needs review

Support multi-index, complex streams as property output in the thread engine

It is required to read data from individual streams and create out of this a single stream which can have a secondary index besides timestamp. This would allow the correlation of individual data streams with each other besides just time series – p...
Hans-Otto Weinhold 4 months ago in Advanced Analytics 0 Needs review