Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 134

Include the Tank functionality in the baseline portion of the product

The Tank table is tied to the LMS apps and does not get exposed on a baseline system where some customers could benefit from its built in nature. Allowing a customer to use the Tank table (and the new FlexTank object) as opposed to a custom reserv...
Guest 11 days ago in Enterprise SCADA Server / Applications 1

Improve the warning/alarm message of the Admin Pager for low Physical Memory threshold

The default wmimonitor alarm message reports "freespace" is below warning\alarm limit for both low physical memory and logical disk. Requesting the messages are updated to be more clear which resource is affected by changing the physical memory me...
Vitali Unke 17 days ago in Enterprise SCADA Server / Alarms 0

Export of the alarm list at Runtime on SA Projects

The export of the alarm list is not present in projects created with the SA template (it was present in old SxW_Style projects). The implementation of an export command requires the inclusion of the Tab_Style_Include project and the use of compone...
Guest about 1 year ago in Plant SCADA / Alarms 2 Submitted

Trend history file modification

Currently any change to a trend in Citect means having to discard the trend history files, for example changing the Sample Period. Would it be possible to have Citect modify the history files automatically? There are tools in the Toolbox to achiev...
Guest over 5 years ago in Plant SCADA / Alarms 1 Future Consideration

Grace period HW alarm

It would be great to get a HW alarm when a license is entering a grace period. It is not every day that you log into the AEL and check the status. Furthermore, it has happened that someone has moved a VM instance to another machine without knowing...
Peter Chung over 2 years ago in Plant SCADA / Alarms 1 Future Consideration

Process Analyst connects to WW Historian

Process Analyst can connect to Citect Historian ,ref to picture. Then is should be possible to connect to Aveva Historian alias WW Historian.
Guest over 5 years ago in Plant SCADA / Alarms 0 In Roadmap

Alarms changes can be pushed to runtime without [Alarm]UseConfigLimits=1

When making alarm changes, sometime you will notice the change does not go through to runtime if you currently have [Alarm]UseConfigLimits=0 This is because the alarm server reads from the database instead of the rdb files, failing to recognize th...
Guest about 1 year ago in Plant SCADA / Alarms 0 Submitted

Logging Citect alarm in Wonderware Historian

Wondering what the plans are for getting the Citect alarm properties in order when logging into AVEVA History. Today if you log alarms from Citect to the Historian you only get AlarmTag, AlarmName and Category as useful data. All other properti...
Guest over 3 years ago in Plant SCADA / Alarms 0 In Roadmap

Process Analyst in dark mode

A complete dark Mode of the Process Analyst is not possible. Some parts of the PA can’t be changed. There are no properties to change the background and foreground color of the toolbar and object view.
Guest over 2 years ago in Plant SCADA / Alarms 2 Future Consideration

SPS version 11 support for RTUPlayer and Trainer.

Requesting support for SPS 11.1 and Windows Server 2022 operating system for RTU Player and Trainer applications.
Andrew Potkins 2 months ago in Enterprise SCADA Server / Applications 0