Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Plant SCADA

Showing 99

Remove more than 1 version in the deployment server at a time

It would be highly beneficial to introduce the capability to remove multiple versions simultaneously. Additionally, an automated feature to retain only the latest 10 versions.
Peter Chung 6 days ago in Plant SCADA / Other 0 Submitted

Remove the Need for pg* Files

Eliminate the requirement for pg*.dbf files. These files are not really needed as the same info is in the .ctg files. These files make it difficult to use PlantSCADA with version control, such as SVN or git since either these files need to be vers...
Guest about 2 years ago in Plant SCADA / Graphics / Visualization 1

OPCUA Variable Import limited to 79 characters

When you import Variable Tags from an OPCUA Server the tag names are truncated to 79 characters, this is sometime not enough. Duplicate tagnames are not allowed. You have to manually adjust all the names. For instance when you connect to a Plant S...
Guest 8 months ago in Plant SCADA / Drivers / Protocols 1

Better keyboard support in Graphics Builder

A lot of potential Graphics Builder tasks can be repetitive, and can be sped up using a keyboard instead of a mouse. But some dialogues are not keyboard friendly. The specific case I have in mind is Tools -> Swap Colours. Opening it from the ke...
Guest 4 months ago in Plant SCADA / Graphics / Visualization 1

Call Excel Addin functions from vba

Whe have our own Excel macro's for generating tags, alarm, trends, etc and would like to use the 64bit version of Excel. We want to open a DBF using the Excel Addin, run our own macro and then save the DBF file using vba.
Guest 2 months ago in Plant SCADA / Development Tools 0 Future Consideration

Search option at Run-time

Search-function similar to what we have in Citect-Studio, but at Runtime. Would be nice to be able to search for a specific tag in order to find which mimic it is used in. Should be possible to click in the search-result and jump directly to the s...
Guest 10 months ago in Plant SCADA / Other 0 Future Consideration

Unify automatic generation of Configuration Parameters in Plant SCADA Studio 2023 and Equipment Editor

Currently when adding new Equipment through Equipment Editor, all relevant Configuration Parameters will be generated automatically and are available in Plant SCADA Studio 2023. However if you add a new Equipment in Plant SCADA Studio and run "Upd...
Guest over 1 year ago in Plant SCADA / Equipment 1

Push all data type of Variables to AVEVA Historian

Currently, The CitectSCADA connector reads Trend tags, SPC, Alarm tags, and Variables (String and Digital data type) info from Plant SCADA and writes data to AVEVA Historian. It would be better to have other data type variables, like Int, Long, re...
Guest 8 months ago in Plant SCADA / Other 3 Unlikely to implement

Fontsize ciode form functions

The posibility to change the fontsize, font used in the cicode form functions.
Guest 4 months ago in Plant SCADA / Graphics / Visualization 0

S7TCP driver issue addressing arrays

Currently the S7TCP driver reads individual element of an array. Need functionality to read array as a whole
Guest 19 days ago in Plant SCADA / Drivers / Protocols 0 Submitted