To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 23 of 791

Improve the warning/alarm message of the Admin Pager for low Physical Memory threshold

The default wmimonitor alarm message reports "freespace" is below warning\alarm limit for both low physical memory and logical disk. Requesting the messages are updated to be more clear which resource is affected by changing the physical memory me...
Vitali Unke about 1 month ago in Enterprise SCADA Server / Alarms 0

Increase Object Containment Level Limit from 10 to 50+

Increase the Object (and Area) Containment Level Limits from 10 to 50 or more. Today we cannot model more than 10 cascaded containment Objects, and we are forced to treat Areas as Objects to adequately represent electrical hierarchy of our power p...
Keary Dosier 5 months ago in Application Server / Configuration 0

OS-Configuration Utility needs an option to not overwrite existing Firewall rules during upgrades.

We are using System Platform 2023----After our normal installation and hardening, we have 22 firewall rules on the system. After installing the SP, (with OS-Configuration Utility) we suddenly have 245 rules. See attachment for details. Requirement...
Guest 12 months ago in Application Server / Configuration / Installation / Security 1

Allow the "safety string" to be moved or disabled in the alarm message

Currently in baseline, (SAFETY) is always added as a prefix to Safety Related alarm messages. It is used as the marker whether the alarm should be recorded in the event table as safety-related. Our customer wants to have (SAFETY) as a suffix for t...
Hugh Arai 3 months ago in Enterprise SCADA Server / Alarms 0

Multi-object properties editing

Ability to modify multiple common properties across several templates at once (e.g., unit of measure, writability, I/O scaling, etc.)
Luca Preziosa 7 months ago in Application Server / Configuration 1

Support multiple MES databases in one GR node

We have multi plants running all local GR nodes with its MESDB. This means one change in the master GR node (offline) must be published on all the sites manually.Would be ideal to have one GR node global, running the objects on the local AOS using...
Guest 4 months ago in Application Server / Configuration 0

Downgrade all OCMC errors and warnings to Info priority about SMS not configured in galaxy.

This Idea is created based on customer feedback from SR: 960579385 End-User would like to have clean OCMC logs if system is working - without unnecessary errors and warnings that are related to SMS configuration disabled.
Guntars Rubenins 8 months ago in Application Server / Configuration 0 Will not implement

(PMFR-479) Alarm Summary display should have a safer mechanism to acknowledge alarms to assure the correct alarm is being acknowledged

Alarm Summary display should have a safer mechanism to acknowledge alarms to assure the correct alarm is being acknowledged PMFR-479
Jake Hawkes over 2 years ago in Enterprise SCADA Server / Alarms 0 Reviewing

PRP (Parallel Redundancy Protocol, IEC 62439-3) support build into the product

Many solutions, especially in the infrastructure world dual networks are standard. ASP relies on Microsoft to manage it via teaming. Teaming does not provide real PRP redundancy. Teaming is also not available on non-server Windows operating system...
Marcell Marjee about 1 year ago in Application Server / Configuration 0

Safety Points support for Connection/Remote records

Enbridge control room operators have requested that the safety points feature, currently available for telemetry points, to be extended to the connection and remote tables. The intent is to allow communication alarms to be flagged, for PLC or site...
Guest over 1 year ago in Enterprise SCADA Server / Alarms 1 Reviewing