To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 10 of 791

Initialize the memory of a variable when switched On using Director command

In Connoisseur we had the capability to re-initialise a specific variable when switching it ON. That is, delete its previous variation history to clear out any inconsistent or untypical behaviour (eg startup). This functionality should be enabled ...
Jan Ledwon almost 3 years ago in APC / General 0 In development

Datapump: Include Port number as an argument to DPDirect process command line

Datapump main process is DPDirect. Two of the arguments are source and destination SQL Services to pump data from one SQL to the other. The most common syntax uses to be like: DPdirect -i 40 -S :MS:<SrcHistorical>\OASYSHDB -D <system>:...
Angel Mario Moreno Arcos almost 2 years ago in Enterprise SCADA Server / Datapump 0

Higher Visibility for Datapump Issues

Request that there be a better way to tell when Datapump is not pumping.
John Bjartveit about 1 year ago in Enterprise SCADA Server / Datapump 0

[Test & DOC] Ability to configure datapump to pull data from an untrusted domain

Big Picture User Experience Officially test and document the feature added to datapump in OASyS 7.6R4 to allow pulling from an untrusted, lower security zone. Detailed Description Customer wants to datapump data from an untrusted domain into a tru...
Tyson Burr over 2 years ago in Enterprise SCADA Server / Administration / Installation / Datapump / Documentation 0 Future consideration

Standard Deviation function for custom calculations

We often need to use SD in calculations. However it is not a standard function available under custom calculations. Please can we add it there.
Geoff Lewis over 2 years ago in APC / General 0 Evaluating

Excel Data import improvements

New feature in 2022 SP1 works great already, but some suggestions for further development: allow import from multiple sheets of Excel workbook if tagname is missing for a particular column, substitute a default (currently the data gets mis-aligned...
Geoff Lewis over 2 years ago in APC / General 0 Evaluating

Convert Raw Tag to Custom

Currently it is possible to convert a Custom Tag to Raw Tag, but not vice versa. This would be v helpful when migrating controllers.
Geoff Lewis over 2 years ago in APC / General 0 Evaluating

Collect doesn't collect current real-time value at top of hour

Customer Requirement Our customers require the ability to maintain complete Timeseries historical trends (collect samples), including timestamped samples polled after a PLC communication loss (outage could be for several hours/days). The customer ...
Guest almost 4 years ago in Enterprise SCADA Server / Historical / Realtime 2 Waiting for information

Alternate timeseries hourly averaging algorithm

Enhancement request to either allow integrators to modify timeseries averaging algorithm or provide hooks to allow integrator to modify the operation. We implemented an alternative timeseries averaging algorithm on many installations. Prior to bin...
Guest almost 4 years ago in Enterprise SCADA Server / Historical / Realtime API/SDK 1

Enhance Datapump to be able to optionally use the FIRE_TRIGGERS option for bulk inserts

We (TCE) would like to find out if Aveva would be able to enhance Datapump to be able to optionally use the FIRE_TRIGGERS option for bulk inserts. We have turned bulk load off for now but would like to see if we could get this enhancement so we co...