To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 12 of 791

Prevent blocked installer from starting

One major cause of issues we see often which causes a lot of work is caused by iso/zip which where not unblocked.Typically it causes different issues and then we have to redo the installations Question : can we please put some effort into checking...
Erik van de Wetering 10 months ago in Application Server / Installation 5 Planned

OS-Configuration Utility needs an option to not overwrite existing Firewall rules during upgrades.

We are using System Platform 2023----After our normal installation and hardening, we have 22 firewall rules on the system. After installing the SP, (with OS-Configuration Utility) we suddenly have 245 rules. See attachment for details. Requirement...
Guest 12 months ago in Application Server / Configuration / Installation / Security 1

Check Computername validity before commencing installation

Check that the computername does not include an "_" or exceed the NetBIOS limit of 15 characters before continuing with installation.
Ernst Van Wyk about 1 year ago in Application Server / Installation 0

Omnicomm retries on temporary connections should retry the connection

On Tech Support case 962469169 it became very clear that when the socket of a temporary connection was broken, Omnicomm would not re-attempt the connection until the next scheduled poll interval (e.g., 5 minutes later). I would expect that if Omni...
Collin Heggerud 3 months ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines 0

Improve Readability of the SuperFlo Verbose Logs

The customer would like the verbose logs recorded by the SuperFlo protocol to more closely resemble those of xMODBUS.
Sean Stovall over 1 year ago in Enterprise SCADA Server / Protocols and Commlines 0

Update SNMP protocol to support v3

Big Picture User Experience Support v3 of the SNMP protocol Detailed Description TBD: any particular SNMP v3 features?
Randy Kostiuk over 2 years ago in Enterprise SCADA Server / Protocols and Commlines 6 Future consideration

Add ability for Omnicomm to support secure connections to devices

Enterprise SCADA desires to be at the forefront of security. Many protocols are beginning to support SSL/TLS connections to the end device, thus finally protecting that last few feet of communications from the networking equipment to the device. F...
Collin Heggerud almost 2 years ago in Enterprise SCADA Server / API / SDK / Developer Relations / Omnicomm / Protocols and Commlines / Security and DMZ 7 Reviewing

Improvements to OPC Client

Enhance the OPC Client such that it can handle third-party OPC Servers that present 10,000+ points as one remote. This "idea" relates to GCS ticket # 960321526.
Craig Parkin about 2 years ago in Enterprise SCADA Server / Protocols and Commlines 1 Waiting for information

IEC-104

IEC60870-101 or IEC60870-104 are the serial and IP versions of what is sometimes refered to IEC-104. These are both part of the IEC60870-5 standard, whereas ICCP is IEC60870-6, and is different. IEC_62351 is a standard for securing the various pro...
Josie Liu almost 6 years ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines / Telemetry 0 Reviewing

Allow protocol specific extensibility of dnlist ADE Form

The dnlist ADE form has protocol specifics built in for BSAP and Fisher ROC but does not allow any extensibility so it is difficult to add "Download by List" functionality to a new protocol (such as DNP3).