Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 26 of 791

Make that the objectviewer executable supports receiving a file name as an argument when it’s launched.

Automation-friendly: Easier to call from batch scripts, cron jobs, or automated workflows. Reduces manual work: No need to manually enter each file name. Works better with auto-generated files: Directly feed the file into the program right after i...
Bram Hertens 11 months ago in Application Server / Diagnostics 0

Improve the warning/alarm message of the Admin Pager for low Physical Memory threshold

The default wmimonitor alarm message reports "freespace" is below warning\alarm limit for both low physical memory and logical disk. Requesting the messages are updated to be more clear which resource is affected by changing the physical memory me...
Vitali Unke about 1 month ago in Enterprise SCADA Server / Alarms 0

Custom Namespaces values in Object Viewer

Enable the ability to view the runtime values of Custom and Standard Namespaces in the Object Viewer.
Luca Preziosa 7 months ago in Application Server / Diagnostics 1

Allow the "safety string" to be moved or disabled in the alarm message

Currently in baseline, (SAFETY) is always added as a prefix to Safety Related alarm messages. It is used as the marker whether the alarm should be recorded in the event table as safety-related. Our customer wants to have (SAFETY) as a suffix for t...
Hugh Arai 3 months ago in Enterprise SCADA Server / Alarms 0

(PMFR-479) Alarm Summary display should have a safer mechanism to acknowledge alarms to assure the correct alarm is being acknowledged

Alarm Summary display should have a safer mechanism to acknowledge alarms to assure the correct alarm is being acknowledged PMFR-479
Jake Hawkes over 2 years ago in Enterprise SCADA Server / Alarms 0 Reviewing

Filtered view in the tree pane for Object Viewer.

The ability to select objects for view based on a filtered list in the tree view rather than having to go through the entire tree view. In this view, you can filter based on text/string and get only the objects or object instances that contain the...
Roan Fourie about 1 year ago in Application Server / Diagnostics 0

Graphics Performance Index summary

My idea is to have a way to get all Graphics performance index for a project when it’s about to close. Instead of of the developers going to the button and check one by one. For commissioning purposes would be very useful to have that list of all ...
Guest about 1 year ago in Application Server / Diagnostics 1

Safety Points support for Connection/Remote records

Enbridge control room operators have requested that the safety points feature, currently available for telemetry points, to be extended to the connection and remote tables. The intent is to allow communication alarms to be flagged, for PLC or site...
Guest over 1 year ago in Enterprise SCADA Server / Alarms 1 Reviewing

Allow aaLogger to display clickable hyperlinks linking to help documentation

Especially useful for warning/error conditions, allowing the user to help themselves, and reduce time delay and GCS calls. Real-world example: I just encountered the following warning and error in the log: Warning DASEngine Data was not passed to ...
John Knox-Davies 8 months ago in Application Server / Diagnostics 0

Alternate alarm limits: support status, multiple trigger states, and a zero-state set to revert to

Configuration Audit Opening the point's events on a record's control panel should show: changes made to the almlimit, and the almlimitset record that it was is assigned to (otherwise changes to limits can be made affecting the point, but they woul...