Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 31 of 776

Events duration column should be a timespan rather than a decimal

When viewing events in AVEVA Advanced Analytics, the duration column shows the event duration as a decimal value representing the number of hours the event was open. For example, a duration of 0.1 = 6 minutes. This is not immediately intuitive, an...
Guest about 1 year ago in Advanced Analytics 0 Needs review

Improvements to OPC Client

Enhance the OPC Client such that it can handle third-party OPC Servers that present 10,000+ points as one remote. This "idea" relates to GCS ticket # 960321526.
Craig Parkin about 2 years ago in Enterprise SCADA Server / Protocols and Commlines 1 Waiting for information

IEC-104

IEC60870-101 or IEC60870-104 are the serial and IP versions of what is sometimes refered to IEC-104. These are both part of the IEC60870-5 standard, whereas ICCP is IEC60870-6, and is different. IEC_62351 is a standard for securing the various pro...
Josie Liu almost 6 years ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines / Telemetry 0 Reviewing

Enhancements to use Device DataQuality: uncertain and error

We request enhancements to the ability for a protocol to indicate data quality to the krunch routines, as first requested in OASYS-518 (API for Protocols to indicate data to be krunched is questionable according to field device): https://aveva.aha...
Collin Heggerud over 1 year ago in Enterprise SCADA Server / Krunch and Data Manipulation / Realtime API/SDK 0

Allow protocol specific extensibility of dnlist ADE Form

The dnlist ADE form has protocol specifics built in for BSAP and Fisher ROC but does not allow any extensibility so it is difficult to add "Download by List" functionality to a new protocol (such as DNP3).
Collin Heggerud over 1 year ago in Enterprise SCADA Server / ADE / PnT / MoC / Protocols and Commlines / Telemetry 1 Will not implement

Enhance Omnicomm to make it easier for protocols to work with sub-remote status indicator.

An enhancement for protocol developers that is standard for all protocols.

Multiple transient state support for multistate command

Detailed Description Due to various physical factors, sometimes a 2-bit status point will transition through both the (valid) TRANSIT state as well as the (invalid) ERROR state, on its way from CLOSED to OPEN (or vice versa). This enhancement will...
Guest over 2 years ago in Enterprise SCADA Server / Alarms / Krunch and Data Manipulation 0 Reviewing

Y2K38 Preparedness

Big Picture User Experience The Year 2038 problem (also known as Y2038, or Y2K38, or the ‘Epochalypse’) is a time datatype bug involving the use a signed 32-bit integer to store of Unix time. The data type is only capable of representing integers ...

Request for year to be added to the runtime structure

We've previously added an additional "year" field to the runtime structure to track hours per year for a 7.5 project. I'd like to request an enhancement to OASyS 2021 to add "year" to the runtime structure please. I see that there's a runtimeyear....
Natalie Hunter almost 4 years ago in Enterprise SCADA Server / Krunch and Data Manipulation / Realtime Schema 5 Will not implement

Offline Rate Integration

Customers on 7.5 system often had a small change made to vdb_rate.cpp, allowing integration to continue even when a point was not fresh, using its last good rate value. This allows calculated volume integrations to match more closely with what oth...
Jake Hawkes almost 5 years ago in Enterprise SCADA Server / Krunch and Data Manipulation 0 Future consideration