To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 39 of 776

Alarm suppression with an analog parent-value comparator.

Alarm suppression with an analog parent-value comparator. Idea collected at Pipeline Summit 2023
Guest almost 2 years ago in Enterprise SCADA Server / Alarms 0

SNMP AES v3

Hi Team, more and more customers are looking to integrate network devices or power devices in system platform via SNMP. But these devices utilize v3 AES most cyber secure encryption mentor. Our drivers only support DES at the moment leading the cu...
Lakshay Mundeja about 1 year ago in Device Integration 2 Planned

Enhance Re-alarming application for any alarm severity

Big Picture User Experience Enable Re-Alarming application to re-alarm alarms of any severity that were acknowledged by SCADA controller Detailed Description Background Re-Alarming application designed to re-annunciate alarms that are previously w...
Guest over 2 years ago in Enterprise SCADA Server / Alarms 1 Future consideration

OPC A&E (and/or OPC UA A&C) to support Areas

We have alarms split into several Areas. When we connect using an OPC AE Client it only shows the correct custom properties for alarms with Area 0. Seems the integrated OPC A&E Server connects to the Alarm database with a user which only can v...
Guest over 3 years ago in Device Integration 1

Mitsubishi FX5U PLC driver for Plant SCADA

MELSECQ protocol can be used to communicate with FX5U, but the addressing system is different. MELSECQ expects Hexadecimal addressing while FX5U expects Octal addressing system.
Jiri Rysavik over 1 year ago in Device Integration 0

How to communicate between Plant SCADA and OMRON PLC NJ series

Among Korean Plant SCADA users, there are often users who use Omron NJ series PLC. They express great inconvenience and dissatisfaction about the lack of communication between Plant SCADA and Omron NJ PLC. The method of changing the address of KB0...
Guest over 1 year ago in Device Integration 0

S7TCP driver issue addressing arrays

Currently the S7TCP driver reads individual element of an array. Need functionality to read array as a whole
Guest over 1 year ago in Device Integration 1

Parent control alarm suppression for ROC alarms

The Chevron 2022 SP1 project is requesting the ability to use Parent control alarm suppression to suppress ROC alarms
Hugh Arai over 1 year ago in Enterprise SCADA Server / Alarms 0

Allow customers to latch alarms

Here is one problem customers are encountering with our alarming philosophy, where we replace the existing alarm with a new one with the current alarm state: Because the alarm for exceeding hi-hi isn’t latched, operators are missing that MAOP was ...
Collin Heggerud over 5 years ago in Enterprise SCADA Server / Alarms / Control Room Management 0

Disable read from certain tags in knx driver

The driver will today read everything after a certain time if not otherwise refreshed. Some tags are not readable and event based only, to avoid uneccesary traffic there should be a possibility to disable read, similar to option for setpoints.
Dan Helgeland over 2 years ago in Device Integration 0