Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 33 of 798

[WWW] Auto-Logon and Logoff - Is there an AVEVA-recommended solution?

Our customer, City of Calgary Water Services, will be upgrading from 7.7 to ES2023 or ES2024. They presently have some batch files in place to automatically log an operator off after a certain length of time and then automatically log in a Read-On...
Serge LeBlanc over 2 years ago in Enterprise SCADA Server / Control Room Management / Security and DMZ 2 Already exists

Enhance Re-alarming application for any alarm severity

Big Picture User Experience Enable Re-Alarming application to re-alarm alarms of any severity that were acknowledged by SCADA controller Detailed Description Background Re-Alarming application designed to re-annunciate alarms that are previously w...
Guest over 2 years ago in Enterprise SCADA Server / Alarms 1 Future consideration

[Test & DOC] Ability to configure datapump to pull data from an untrusted domain

Big Picture User Experience Officially test and document the feature added to datapump in OASyS 7.6R4 to allow pulling from an untrusted, lower security zone. Detailed Description Customer wants to datapump data from an untrusted domain into a tru...
Tyson Burr over 2 years ago in Enterprise SCADA Server / Administration / Installation / Datapump / Documentation 0 Future consideration

Parent control alarm suppression for ROC alarms

The Chevron 2022 SP1 project is requesting the ability to use Parent control alarm suppression to suppress ROC alarms
Hugh Arai almost 2 years ago in Enterprise SCADA Server / Alarms 0

Allow customers to latch alarms

Here is one problem customers are encountering with our alarming philosophy, where we replace the existing alarm with a new one with the current alarm state: Because the alarm for exceeding hi-hi isn’t latched, operators are missing that MAOP was ...
Collin Heggerud almost 6 years ago in Enterprise SCADA Server / Alarms / Control Room Management 0

NMC should not log confusing messages if the ADLDS Cross Domain Replication sender is also a receiver from another ADLDS realm

The current 2023 system designs being provided to customers include an es/deployment system with it's own ADLDS realm. AOR area/group changes are made there first and it is the global table owner for its realm. The primary production system is set...
Hugh Arai about 2 years ago in Enterprise SCADA Server / Administration / Installation / Replication 0 Reviewing

Support OS live upgradability

Big Picture Support live OS upgradability after Enterprise SCADA has been upgraded to v2023, without the need for a cold start. Detailed Description It is currently assumed that it will be required to update the OS from one major version to the ne...
Jake Hawkes about 2 years ago in Enterprise SCADA Server / Administration / Installation / Architecture 0 Reviewing

Multi-system support for HMI

User Story As a pipeline operator / supervisor monitoring pipeline assets that span multiple RealTime environments, I would like to be able to connect my HMI to the combined multi-RealTime environment, conferring all benefit of functionality co...
Tyson Burr over 4 years ago in Enterprise SCADA Server / Architecture / Control Room Management 1 Future consideration

Address nuisance error log messages related to the Trend BLT

Detailed Description Request that the Recordset open error be moved to ALWAYS as it does provide insight into an issue with trending a point 2022-05-16 12:18:36.744 [TID=0x299c] WARNING: Trend: numCollects: Recordset open (execute) failed [-214721...
Serge LeBlanc over 2 years ago in Enterprise SCADA Server / Administration / Installation 1 Future consideration

Request disabling NetBios be validated

This request created created from a Pembins 2018 SP3 inquiry but I believe it has been agreed to only be considered for supported versions or future release. Previous IMS from ConEd - 2178824 was closed stating, "noting they need to validate the c...
Serge LeBlanc over 2 years ago in Enterprise SCADA Server / Administration / Installation / Architecture / Security and DMZ 1 Planned