To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Add 'Workstation Administrator' Role to Active Directory

Big Picture User Experience Following the Principle of Least Privilege, AD-Tiering and now Enterprise Access Model , add 'Workstation Administrator' Role to Active Directory to enable a separation of duties between server administrators and deskto...
Julian Reyes Riveros over 3 years ago in Enterprise SCADA Server / Security and DMZ 0 Planned

[Test & DOC] Ability to configure datapump to pull data from an untrusted domain

Big Picture User Experience Officially test and document the feature added to datapump in OASyS 7.6R4 to allow pulling from an untrusted, lower security zone. Detailed Description Customer wants to datapump data from an untrusted domain into a tru...
Tyson Burr over 3 years ago in Enterprise SCADA Server / Administration / Installation / Datapump / Documentation 0 Future consideration

Increase FlowTotalConfig totalblocks from 4 to 6

Increase the total blocks from 4 to 6 (1 additional as a spare)to enable additional elements to be calculated within one flowTotalConfig Flow Rate [0]Current Hour Accum [1]Previous Hour Accum [2]Current Day Accum [3]Current Month Accum [4]
Vitali Unke almost 2 years ago in Enterprise SCADA Server 0 Future consideration

Higher Visibility for Datapump Issues

Request that there be a better way to tell when Datapump is not pumping.
John Bjartveit almost 2 years ago in Enterprise SCADA Server / Datapump 0

flowTotalConfig integration blocks replication enhancement request

Our customer has a business need to be able to manually adjust previous hour/day/month etc of a flowTotal record. So that it provides accurate information in the control room so that GCN records can be met and gas used can be properly tracked.Ofte...
Vitali Unke almost 2 years ago in Enterprise SCADA Server 0

MoC Extensions Disabled by Default

As a system integrator I would prefer to see MoC extensions disabled by default, to be enabled if needed, in order to remove this from the required lists of tasks to be executed for a system installation having MoC.
Tyson Burr about 2 years ago in Enterprise SCADA Server 0

Make LogViewer File->Open default to folder of currently open log file

Big Picture User Experience Make LogViewer File->Open default to folder of currently open log file Detailed Description Currently, when a user opens a log file, and then attempts to open another log file, the file->open dialog box always def...
Jake Hawkes about 2 years ago in Enterprise SCADA Server 0 Will not implement

Allow customers to latch alarms

Here is one problem customers are encountering with our alarming philosophy, where we replace the existing alarm with a new one with the current alarm state: Because the alarm for exceeding hi-hi isn’t latched, operators are missing that MAOP was ...
Collin Heggerud over 6 years ago in Enterprise SCADA Server / Alarms / Control Room Management 0

ADE permit to use symbols (),.-/

On ADE, Address1 and Address2 fields in the Station table of ADE do not permit the use of symbols such as (),.-/, even though these characters can be part of legitimate addresses.
Gerald Tseng over 2 years ago in Enterprise SCADA Server / ADE / PnT / MoC 0

Alternate timeseries hourly averaging algorithm

Enhancement request to either allow integrators to modify timeseries averaging algorithm or provide hooks to allow integrator to modify the operation. We implemented an alternative timeseries averaging algorithm on many installations. Prior to bin...
Guest over 4 years ago in Enterprise SCADA Server / Historical / Realtime API/SDK 1