To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

SQL outside Cicode or mechanism for inserting data into different database with specific period

When we want use 3rd party tool like Grafana , Node Red, Wordpress and many others we need data from different database. Need a mechanism for transferring data from trend files to the database like MSSQL. MongoDB, MariaDB, MySQL but without write ...
Guest over 1 year ago in Plant SCADA / Historic Data / Storage 5 Unlikely to implement

Add a method to export/import Custom properties in a aagraphic

it would be suitable to have export import of Custom Properties directly in the graphic editor - The actual workaround in the 2026 version would be export graphic as XML edit the XML and import it
Ernst Van Wyk 3 months ago in Application Server / Graphic Editor 0

Dynamically modify the EngUnits field of an attribute at runtime.

Need to dynamically modify the EngUnits field of an attribute at runtime. Currently this is not possible via script or Object Viewer.
Giuseppe Acampora 5 months ago in Application Server / Object Editor 0

Add Area Hierarchy Filter/Query Support for OMI Alarm App in Historical Alarm Mode

In the Current Alarms mode, users can easily view alarms by area using the Area Hierarchy if shown. However, if you show the Hierarchy menu when the Alarm App is in Historical Alarms mode, selecting an area has no effect on the returned alarms. Us...
Laura Morris about 1 year ago in Application Server / Alarm App 0

Add Search of arbitrary text

As of version 2023R2 the "Find" window is only usable to find Instances, Templates or Attributes by name. In addition it should allow searching for arbitrary text inside templates/instances scripts, IG symbols (scripts and animations), OMI Layout ...
Rares Plesea over 1 year ago in Application Server / IDE 1

Export/Print list of objects belonging to specifical security group

Add the possibility to export/print a list of objects belonging to the selected Security Group, in Galaxy Security Groups Configuration. Today, the only option to create such list is to export selected objects for example from deployment view to C...
Antonina Nilsson 9 months ago in Application Server / IDE 0

Trend history file modification

Currently any change to a trend in Citect means having to discard the trend history files, for example changing the Sample Period. Would it be possible to have Citect modify the history files automatically? There are tools in the Toolbox to achiev...
Guest over 6 years ago in Plant SCADA / Alarms 1 Future Consideration

Improvements of the deployment functionality

Deploying a project can be slow, especially upoading a new version of the project. A progression bar with remaining time would be nice. Would be a nice feature if you could upload the complete project including the configuration files. Have an opt...
Guest over 3 years ago in Plant SCADA / Development Tools 6 Reviewed & Categorized

Allow ContentType User_Defined_# to be named

The generic User_Defined_1, _2, ...N is useless. When a graphic is created the developer may need to use a User Defined but would not know if User_Defined_1 is already used for something else. Nor would the developer know to use User_Defined_1 for...
Lonnie Purvis over 1 year ago in Application Server / Industrial Graphics 0

OPCUA Variable Import limited to 79 characters

When you import Variable Tags from an OPCUA Server the tag names are truncated to 79 characters, this is sometime not enough. Duplicate tagnames are not allowed. You have to manually adjust all the names. For instance when you connect to a Plant S...
Guest almost 3 years ago in Plant SCADA / Drivers / Protocols 2 Reviewed & Categorized