To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 175 of 776

OS-Configuration Utility needs an option to not overwrite existing Firewall rules during upgrades.

We are using System Platform 2023----After our normal installation and hardening, we have 22 firewall rules on the system. After installing the SP, (with OS-Configuration Utility) we suddenly have 245 rules. See attachment for details. Requirement...
Guest 11 months ago in Application Server / Configuration / Installation / Security 1

Check Computername validity before commencing installation

Check that the computername does not include an "_" or exceed the NetBIOS limit of 15 characters before continuing with installation.
Ernst Van Wyk about 1 year ago in Application Server / Installation 0

SPS version 11 support for RTUPlayer and Trainer.

Requesting support for SPS 11.1 and Windows Server 2022 operating system for RTU Player and Trainer applications.
Andrew Potkins 2 months ago in Enterprise SCADA Server / Applications 0

Language assistant should support internationalized strings

Language assistant is not so useful when Internationalized strings are missing: If it is recommended by Aveva to use Language Assistant when translating phrases, it would be good if it supports Internationalized strings also. Now they have to be m...
Guntars Rubenins 7 months ago in Application Server / Localization 0

Allow the "safety string" to be moved or disabled in the alarm message

Currently in baseline, (SAFETY) is always added as a prefix to Safety Related alarm messages. It is used as the marker whether the alarm should be recorded in the event table as safety-related. Our customer wants to have (SAFETY) as a suffix for t...
Hugh Arai 3 months ago in Enterprise SCADA Server / Alarms 0

Omnicomm should better support modern network speeds

Omnicomm has a feature that allows it to wait longer for large messages than for short messages. This feature defaults to calculations based on messages transmitted at 1200bps and has a maximum configurable rate of 38400bps. In a world where many ...
Collin Heggerud 3 months ago in Enterprise SCADA Server / Omnicomm 0

Omnicomm retries on temporary connections should retry the connection

On Tech Support case 962469169 it became very clear that when the socket of a temporary connection was broken, Omnicomm would not re-attempt the connection until the next scheduled poll interval (e.g., 5 minutes later). I would expect that if Omni...
Collin Heggerud 3 months ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines 0

Allow chained VDB field put overrides so integrators can override baseline fields

During development of some CIP functionality for [a customer], (EXT-417), we needed to trigger some protocol specific functionality when the "poll group" field changes. However, when we added a VDB override, it wasn't called. [R&D Architect] h...
Collin Heggerud over 1 year ago in Enterprise SCADA Server / Realtime API/SDK 1 Reviewing

Make Inhibit State/Alarm Limits persist across redeployment of objects.

In all of our client's systems, we give them the ability to modify both the alarm limit/mode for analog alarms, and to inhibit tags that contain alarms (supervisors only). Problem is that if these tags are then redeployed without preserve runtime ...
Guest 8 months ago in Application Server / Alarming 0

Allow Containment across Area/Object boundary

Besides derivation there are three other parent-child relationships in System Platform: Host refers to the parent of an object in Deployment view and indicates where an object executes Container refers to the parent of an object in Model view with...
Ernst Van Wyk over 1 year ago in Application Server / Application Server Runtime / Development / IDE 0