To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Remove Engine Option

Kill Platform is a good utility that is available to remove Platform if its stuck in deployment/undeployment however nothing like that exists for engine. But most of the times, the platform i& other engines are working fine. A utility to remov...
Lakshay Mundeja over 1 year ago in Application Server / Application Server Runtime 2

Upgrade the MAXIMUM LENGHT for STRING and CITECT.INI Parameters over 254 characters !

As discussed in TN000028481 , the MAXIMUM LENGHT for STRING and CITECT.INI Parameters is 254 characters ! This cause many problems inside CICODE SCRIPTS (this limit is too strong in modern world!) and in [Event] parts of citect.ini (you must reduc...
Guest over 3 years ago in Plant SCADA / Development Tools 0 Reviewed & Categorized

Modification Request to Alarm Suppression Functionality

When a Parent point goes stale, alarm suppression associated with that point is removed.
Rob Kenny 2 months ago in Enterprise SCADA Server / Alarms 1 Will not implement

Reading 64-Bit Double (Float) in OPC UA as a String

Energy meters and sensors often are using IEEE double precision (64 bit) floating point datatypes for counters and totalizer. Reading this Items as a string from the OPC server and then convert it in a Real Data type Cicode Variable can allow us ...
Guest over 6 years ago in Device Integration 2

Galaxy Dump

We need dump features of all galaxy objects (grapical object too), scripts and so on to be able to find information in a wide mode
Guest 5 months ago in Application Server / Other 0

Access Anywhere automatically pops up keyboard

In the customer's project, they needs Access Anywhere on a touch screen device (most probably Android). The tablet user would need to type in a string value into an input box. When clicking on it with a PC, the popup allows you to type a string us...
Guest about 1 year ago in Plant SCADA / Other 3 In Development

Industrial Graphic script editor should ask for saving on Exit after ESC key press

When writing some scripts in Industrial Graphic editor, if we press ESC key by mistake, it closes, no matter if there was a script modified or written without asking for saving or not. So instead using Script editor i always write script in Notepa...
Marcin Wozniczka over 1 year ago in Application Server / Scripting 2

Process Analyst in dark mode

A complete dark Mode of the Process Analyst is not possible. Some parts of the PA can’t be changed. There are no properties to change the background and foreground color of the toolbar and object view.
Guest about 3 years ago in Plant SCADA / Alarms 2 Future Consideration

Display quality as string intead of Hex in OCMC (SMC)

Hex value indicating the quality of the items in OI Server Device Groups (Diagnostics) is not easily readable. I suggest to replace the Hex values by their String value, or display Hex value and string value like in Object Viewer (eg: C0:Good)
Florian Champalle almost 2 years ago in Device Integration 0 Planned

Add 'Go To Definition' in Cicode Editor

Allow the user to right click on a User Defined Cicode Function within a code segment and select 'Go To Definition' to navigate to the selected function definition. Optionally provide the ability to select 'Back' to navigate to last cursor positio...
Guest over 6 years ago in Plant SCADA / Development Tools 0 Future Consideration