Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 591

Change the IP address of a controller using a parameter for S7TCP and other protocols

For communicating with S7 controllers you would use PSDIRECT in the past. For this protocol the IP Address of the controller is in the backend configuration. For S7-1500 you can use S7TCP, this has the IP address in the Address field of the I/O De...
Guest almost 2 years ago in Device Integration 0

VSCode / Cicode Editor

Provide a language (Cicode) template / library that can be imported into VSCode. This would allow for some additional features that are sorely lacking in the Cicode editor. For example linting tools.
Guest about 3 years ago in Plant SCADA / Development Tools 2

A function to get the number of display clients connected to a server process

Existing ServerInfoEx() function gives the number of server side Trans of a specified service type but there is no way to get the number of display clients connected to a server.
Guest over 4 years ago in Plant SCADA / Other 0 Future Consideration

Right click on a alarm - Navigate

I have a customer who wishes that users with insufficient privileges are not allowed to "Navigate" to the alarm. So basically. The same behavior as acknowledging and shelving that is greyed out (See the attached picture). Or at least have an optio...
Peter Chung 9 months ago in Plant SCADA / Alarms 0

3D visual comparison

very often the 2d visual comparison can't show clear correlations between two parameters because of the influence of a 3rd parameter, a 3D visual comparison would show user clearly how signals are inter-correlated with a higher dimension. a exampl...
Jason Tan almost 2 years ago in Predictive Analytics / Model Builder Client 2 Tell us more

multi constraint function

to be able to constraint multiple project points in one model. it is useful for equipment with multiple control setpoints such as a distillation column or furnace. in these two cases operator has the freedom to independently adjust multiple contro...
Jason Tan almost 2 years ago in Predictive Analytics / Model Builder Client 0 Evaluating

Are there plans in the future to add water level to tanks?

Batch transfer application has the capability of compensating for sediment and water in order to calculate an NSV. A batchXfer record can be configured with an S&W (%) input analog for the purpose. Is there any plan to adopt that into tanking ...
Guest 9 months ago in Pipeline Operations for Liquids 1

Add {equipment.ItemName} to reference objects in Equipment Editor

When working with a PLC that uses name based tags, such as Rockwell Control Logix 5000 series, creating equipment results in repetitive typing or copy and pasting which is not only time consuming, but adds possible user error when entering tags. F...
Guest about 3 years ago in Plant SCADA / Development Tools / Equipment 1

Modify the language DBFs from the Plant SCADA Studio

Instead of using Excel (or any other DBF editor) use the Plant SCADA Studio to modify the english.dbf, dutch.dbf of any other language . There is already a Setup -> Languages grid
Guest almost 2 years ago in Plant SCADA / Development Tools 0

Expose scripts in Industrial Graphics

When printing an application, this allows us to understand all scripts in InTouch. Anything within Industrial Graphics isn't included. There should be a mechanism to show all scripts in the graphics for troubleshooting and optimization.
Andrew Flournoy 3 months ago in InTouch HMI 1