Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Enterprise SCADA Server

Showing 100 of 709

Configure a commanded status point to alarm in abnormal state

Customer desires the ability to configure status points so that an alarm is generated when a status point is commanded to (and enters) an abnormal state. Attaching use case as described by customer in SC 960445947
Guest 11 months ago in Enterprise SCADA Server 1

ADLDS default configuration for sound alerts in AdminPager, and user-level preferences that do not require starting the application

Big Picture User Experience Make AdminPager react to the user's options preference (i.e. no sound immediately), and persist for that user on a machine by machine basis.Make AdminPager set the default Option to those stored in AD for the computer i...
Guest 12 months ago in Enterprise SCADA Server 0 Reviewing

Increase FlowTotalConfig totalblocks from 4 to 6

Increase the total blocks from 4 to 6 (1 additional as a spare)to enable additional elements to be calculated within one flowTotalConfig Flow Rate [0]Current Hour Accum [1]Previous Hour Accum [2]Current Day Accum [3]Current Month Accum [4]
Vitali Unke 7 months ago in Enterprise SCADA Server 0 Future consideration

Higher Visibility for Datapump Issues

Request that there be a better way to tell when Datapump is not pumping.
John Bjartveit 8 months ago in Enterprise SCADA Server / Datapump 0

Alarm suppression with an analog parent-value comparator.

Alarm suppression with an analog parent-value comparator. Idea collected at Pipeline Summit 2023
Guest over 1 year ago in Enterprise SCADA Server / Alarms 0

Add API for protocols to update freshness of point independently from field value

Big Picture User Experience Omnicomm API to allow protocols to update DQ and value with 4 permutations. Bad Quality only, Bad quality With value, Good Quality only and Good Quality with Value. Detailed Description With adoption of more sophisticat...
Collin Heggerud over 1 year ago in Enterprise SCADA Server 1 Waiting for information

Enhance water-sqrt rate subtype

TS analysis: TS has confirmed that water-sqrt has been an available choice for the rate subtype in 2018 through 2023.(water-sqrt.PNG attached) However, the documentation for rate subtype only lists and describes the other 3 options - linear, liqui...
Natalie Hunter over 1 year ago in Enterprise SCADA Server 2 Reviewing

CRM Point to Point Verification Enhancement

To address PHMSA finding and to improve commissioning experience, we are looking to add the following data fields to CRM database and improve the existing display to support the fields. Field (with examples) Description Engg Units (Pull from datab...
Guest over 1 year ago in Enterprise SCADA Server / Applications 0

Dnaswana with DALPrompter

Dnaswana needs the ability to be run on a system that has no RealTime server. For example, GRT project uses support computers on RDS systems (with no Realtime services on there) and needs to run dnaswana from those computers and get traffic data f...
Vitali Unke over 1 year ago in Enterprise SCADA Server / Architecture / Omnicomm / Security and DMZ 0

flowTotalConfig integration blocks replication enhancement request

Our customer has a business need to be able to manually adjust previous hour/day/month etc of a flowTotal record. So that it provides accurate information in the control room so that GCN records can be met and gas used can be properly tracked.Ofte...
Vitali Unke 9 months ago in Enterprise SCADA Server 0