To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 241 of 776

Support for Win 11 and Server 2025 LTSC versions

Big Picture User Experience Next release of Enterprise SCADA to support of the next MSFT stack of new Operating systems. Detailed Description Windows 11 LTSC and Windows Server 2025 are due to be released before Dec 31 2024. We must support these...
Vitali Unke about 1 year ago in Enterprise SCADA Server 0 Reviewing

Enhance ACE to be triggered by timestamp for any record in Realtime

IMS# 1766330 Customer was using inchtime.high to trigger an ACE routine from an RtString record. A defect was fixed that stopped the timestamps being published via PubSub, which caused ACE to stop triggering. The proposed fix is to allow ACE to be...
Jake Hawkes over 1 year ago in Enterprise SCADA Server 0

[OADC] Support AD-Tiering and VM Hosts

Big Picture User Experience Enhance the OADC tool to support AD-Tiering when installing and upgrading Enterprise SCADA Use Cases The product should install into an AD structure that complies with the intention of AD-tiering, which has since evolve...
Jake Hawkes over 1 year ago in Enterprise SCADA Server 0 Reviewing

Add alarm delay for digital points

Big Picture User Experience Add On/Off alarm delay for digital points (status and multistate) in the same fashion as for analog. Detailed Description The product currently enables the configuration of analog points to delay alarm generation and su...
Jake Hawkes over 1 year ago in Enterprise SCADA Server 0 Reviewing

Reaching dataset limit prevents system to operate without any user feedback that the limit has been reached

This feature is to address and issue where customer has reached maximum number of datasets allowed (currently it is around 25 I believe - increased from 10 to satisfy some short term requirements). This feature is added to address comment from PMF...
Jake Hawkes over 1 year ago in Enterprise SCADA Server 0

Archive should not spam alarm summary when the disk fills.

Archive should not spam alarm summary when the disk fills. Currently, the alarm process creates a new alarm for every table that it is attempting to process when failures occur. This results in the alarm summary not displaying operational alarms.
Jake Hawkes over 1 year ago in Enterprise SCADA Server 0 Reviewing

Allow CGL to reuse meter run configuration resulting in better configuration experience

No description provided
Vitali Unke over 1 year ago in Enterprise SCADA Server 0 Reviewing

EPCO: Alternate Alarm Limit Enhancements

Big Picture User Experience Enterprise is asking for the following enhancements to Alternate Alarm Limits: opening the point's events on a record's control panel should show: changes made to the almlimit, and the almlimitset record that it was i...
Vitali Unke over 1 year ago in Enterprise SCADA Server 0 Reviewing

Deprecate the groupArray field and datatype in the Area table

Big Picture User Experience Deprecate both the area field and the groupArray type in the realtime schema. Detailed Description The groupArray field holds information that was synced from ADAM. It is currently hard-limited to 20 groups, whereas the...
Vitali Unke over 1 year ago in Enterprise SCADA Server 0 Will not implement

Ability to run cmxrepclient and DPutil from a non-realtime server

Email from GCS / Customer: "According to the new architecture in which the Realtime and Historical servers are installed with Windows CORE; we need to run all OASyS tools from the Support Server, especially during a Mode Switch, in which we need t...