To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Enterprise SCADA Server

Showing 53 of 470

GroupArea in the area table only contains the first 20 groups

Do we actually have a limit of 20 groups per area? Some testing has shown that one can add more then 20 groups into an area. The GroupAreaJoin table populates all of them correctly however the "group[0-19].name” array-field in the area table only ...
Brad Tomanik 10 months ago in Enterprise SCADA Server / Administration / Installation / Realtime 1 Already exists

User alarm limits should obey existing alarm deadbanding configuration

After configuring user alarms using the “user hi” and “user lo” functionality, alarms are being generated without consideration for the alarm level deadband configured for the point. For example: A user high alarm configured at 100 will ring into ...
Guest 10 months ago in Enterprise SCADA Server / Alarms 0 Reviewing

Add 'Workstation Administrator' Role to Active Directory

Big Picture User Experience Following the Principle of Least Privilege, AD-Tiering and now Enterprise Access Model , add 'Workstation Administrator' Role to Active Directory to enable a separation of duties between server administrators and deskto...
Julian Reyes Riveros 11 months ago in Enterprise SCADA Server / Security and DMZ 0 Planned

Multiple transient state support for multistate command

Detailed Description Due to various physical factors, sometimes a 2-bit status point will transition through both the (valid) TRANSIT state as well as the (invalid) ERROR state, on its way from CLOSED to OPEN (or vice versa). This enhancement will...
Guest 11 months ago in Enterprise SCADA Server / Alarms / Krunch and Data Manipulation 0 Reviewing

User alarm limits should obey existing alarm deadbanding configuration

Big Picture User Experience User alarm limits should obey existing alarm deadbanding configuration Detailed Description After configuring user alarms using the “user hi” and “user lo” functionality, alarms are being generated without consideration...
Guest 11 months ago in Enterprise SCADA Server 0 Reviewing

Enhance Datapump to be able to optionally use the FIRE_TRIGGERS option for bulk inserts

We (TCE) would like to find out if Aveva would be able to enhance Datapump to be able to optionally use the FIRE_TRIGGERS option for bulk inserts. We have turned bulk load off for now but would like to see if we could get this enhancement so we co...
Rob Kenny 12 months ago in Enterprise SCADA Server / Datapump 0 Will not implement

Re-think, and re-design the PI interface

Background The current PI-OASyS interface was designed for the 7.4 version of OASyS. This interface will remain supported for all versions it was released with. It uses OSIsoft APIs/SDKs which are practically EOL, and are certainly no longer evolv...
Jake Hawkes about 4 years ago in Enterprise SCADA Server / OSIsoft PI 0 Planned

Make Email Alarms generic to support 3rd party notification systems

No description provided
Jake Hawkes about 1 year ago in Enterprise SCADA Server 0 Future consideration

Allow customers to latch alarms

Here is one problem customers are encountering with our alarming philosophy, where we replace the existing alarm with a new one with the current alarm state: Because the alarm for exceeding hi-hi isn’t latched, operators are missing that MAOP was ...
Collin Heggerud about 4 years ago in Enterprise SCADA Server / Alarms / Control Room Management 0

IEC-104

IEC60870-101 or IEC60870-104 are the serial and IP versions of what is sometimes refered to IEC-104. These are both part of the IEC60870-5 standard, whereas ICCP is IEC60870-6, and is different. IEC_62351 is a standard for securing the various pro...
Josie Liu about 4 years ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines / Telemetry 0 Reviewing