To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Enterprise SCADA Server

Disable File type association setting

No description provided
Vitali Unke 8 months ago in Enterprise SCADA Server 1 Will not implement

Configure a commanded status point to alarm in abnormal state

Customer desires the ability to configure status points so that an alarm is generated when a status point is commanded to (and enters) an abnormal state. Attaching use case as described by customer in SC 960445947
Guest about 2 years ago in Enterprise SCADA Server 1

Expand gas measurement krunch items beyond arbitrary limit of 1022

Meter config upload limits hard-coded based on older Mercury devices and don't support newer Mercury devices. I believe this is a defect in the API, but have been asked to submit as an enhancement.
Collin Heggerud 9 months ago in Enterprise SCADA Server 0

Enhance NMC to be more descriptive as to what resource the "FreeSpace" monitoring/alarm is for

Has this functionality been delivered before?: It is configurable today, but must be done on every machine individually. In large installs, this is a large effort. Links OGPM: http://tcjira.aveva.com/browse/OGPM-3091
Tyson Burr almost 3 years ago in Enterprise SCADA Server / Administration / Installation / Architecture 0 Future consideration

Point Conditioning application should support point conditioning updates from multi threaded callers

[customer] experienced lock contention issues when updating point conditioning inputs from within ACE code. Investigation into this issue in support case https://gcsservicecloudutils.azurewebsites.net/casedetails?casenumber=960273706 and R&D I...
Andrew Potkins over 1 year ago in Enterprise SCADA Server / Realtime 0

Safety Points support for Connection/Remote records

Enbridge control room operators have requested that the safety points feature, currently available for telemetry points, to be extended to the connection and remote tables. The intent is to allow communication alarms to be flagged, for PLC or site...
Guest over 2 years ago in Enterprise SCADA Server / Alarms 2 Reviewing

SPS version 11 support for RTUPlayer and Trainer.

Requesting support for SPS 11.1 and Windows Server 2022 operating system for RTU Player and Trainer applications.
Andrew Potkins 11 months ago in Enterprise SCADA Server / Applications 0

Alternate alarm limits: support status, multiple trigger states, and a zero-state set to revert to

Configuration Audit Opening the point's events on a record's control panel should show: changes made to the almlimit, and the almlimitset record that it was is assigned to (otherwise changes to limits can be made affecting the point, but they woul...
Guest almost 3 years ago in Enterprise SCADA Server / Alarms 0

Allow the "safety string" to be moved or disabled in the alarm message

Currently in baseline, (SAFETY) is always added as a prefix to Safety Related alarm messages. It is used as the marker whether the alarm should be recorded in the event table as safety-related. Our customer wants to have (SAFETY) as a suffix for t...
Hugh Arai 11 months ago in Enterprise SCADA Server / Alarms 0

Omnicomm should better support modern network speeds

Omnicomm has a feature that allows it to wait longer for large messages than for short messages. This feature defaults to calculations based on messages transmitted at 1200bps and has a maximum configurable rate of 38400bps. In a world where many ...
Collin Heggerud 11 months ago in Enterprise SCADA Server / Omnicomm 0