To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 769 of 769

Remove the Need for pg* Files

Eliminate the requirement for pg*.dbf files. These files are not really needed as the same info is in the .ctg files. These files make it difficult to use PlantSCADA with version control, such as SVN or git since either these files need to be vers...
Will Herndon over 3 years ago in Plant SCADA / Graphics / Visualization 1

Increase Uptime by Retrieving License Statuses for Alarming in OMI/WIN-911 from SP

The System Monitor has a rule category called "License Server Alerts". This allows the monitor to catch; "Alert on licenses that expire within X day(s)", for example. Additionally, through the rule category named "SMC Logger (Filter)" it is possib...
Jørgen Myklebust 9 months ago in Application Server / Alarming 2

Ability to Integrate IDE with standard source control tools (i.e. GIT, TFS, SVN)

With the discontinuation of Autosave 4 System Platform, the IDE is lacking any ability for doing source control. It would be great to have this as a native feature. Use Case 1 : Developers tracking code changes, DIFF, rolling back code, etc… Ideal...
Jim MacDonald over 1 year ago in Application Server 1

Properly handling default values and locks in the IDE

Currently users use the lock functionality to set a default value for an attribute but this locks the value at instance level and at every template level in between the configured template and the instances. It means that users need to go back and...
Ernst Van Wyk over 1 year ago in Application Server / IDE 3 Planned

Long Term Servicing for PlantSCADA

Standard Term Servicing is provided by AVEVA for all Citect versions which includes 3 years of full support. After the 3 years the following support is dropped. Minor and Major version releases Patches to address non-critical issues Ability to req...
Guest 7 months ago in Plant SCADA / Other 2 In Roadmap

Modify in runtime the text for an attribute with Data type Internationalized String

Since 2023 R2 release, some string attributes are now with the Internationalized String data type. And the inherited negative effect is that we can no longer edit the text in runtime for a description attribute. Indeed, as part of a continuous imp...
jacki denis 8 months ago in Application Server / Compatibility 0

BACNET: Addressing objects via ObjectName

We have several requests for accessing BACNET objects via their "ObjectName", rather than their HW address ie: AI.1.PresentValue. There are 2 issues with the current way of addressing: Makes it difficult to make equipment Some PLC’s (ie Wago) shif...
Guest over 5 years ago in Device Integration 1

Re-enable viewing utilities in the read-only OMI Layout editor

The Read-Only variant of the OMI Layout editor has numerous viewing and navigation features disabled that severely limit its usefulness. As these features do not modify the content of the layout, they should be enabled to improve developer experie...
Rob Budak 8 months ago in Application Server / Layout Editor 1

S7TCP support for firmware V3.0 with username and password

To increase security this option is available on the S7-1500 controller. Without a username and password anyone connected to the network can connect, browse and change values.
Guest over 1 year ago in Device Integration 4

Remove more than 1 version in the deployment server at a time

It would be highly beneficial to introduce the capability to remove multiple versions simultaneously. Additionally, an automated feature to retain only the latest 10 versions.
Peter Chung over 1 year ago in Plant SCADA / Other 0