Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Allow IO feature for array attributes

When using the object editor, the IO feature is not available for array types. Reading array data is very basic functionality and the inability to do this creates very messy objects.
Andrew Drane 8 months ago in Application Server / Object Editor 1

[PlantSCADA] Ability to Historize other Data Type (like INT/REAL)

4.1 Be able to Historize other Data Type (like INT/REAL) of tag variables , not just the Digital/String Data Types Looks like this is done by choice or some other reasons, e.g. name clashes. The Connector code currently explicitly filters out vari...
Marcell Marjee 12 months ago in Historian & Client / Data Acquisition 0 In Roadmap

Remove the Need for pg* Files

Eliminate the requirement for pg*.dbf files. These files are not really needed as the same info is in the .ctg files. These files make it difficult to use PlantSCADA with version control, such as SVN or git since either these files need to be vers...
Will Herndon over 4 years ago in Plant SCADA / Graphics / Visualization 1 Reviewed & Categorized

Increase Uptime by Retrieving License Statuses for Alarming in OMI/WIN-911 from SP

The System Monitor has a rule category called "License Server Alerts". This allows the monitor to catch; "Alert on licenses that expire within X day(s)", for example. Additionally, through the rule category named "SMC Logger (Filter)" it is possib...
Jørgen Myklebust over 1 year ago in Application Server / Alarming 2

Bulk Copy of Custom Property Values Between Embedded Symbols

Problem Statement When two embedded symbols in the graphics editor share identical custom property definitions but differ in their default values, users must manually enter the correct default values for each property in the target symbol. This ma...
Ernst Van Wyk about 1 year ago in Application Server / Graphic Editor 0

BACNET: Addressing objects via ObjectName

We have several requests for accessing BACNET objects via their "ObjectName", rather than their HW address ie: AI.1.PresentValue. There are 2 issues with the current way of addressing: Makes it difficult to make equipment Some PLC’s (ie Wago) shif...
Guest over 6 years ago in Device Integration 1

Enable use user credential in Application Server OPC UA server

Hi, Aveva Application Server can be used as an OPC UA server to expose Atrtibutes to OPC UA Clients. If we are using OPCUA Communication driver we cannot use a security , only anonymous is supported. We want to enable the use of User Credentials i...
Guest 2 months ago in Application Server / Application Server Runtime 0

Be able to see eg an icon on my IDE when someone else is deploying and when it is done.

I would like some sort of indication when someone else is busy deploying and also see once he is done. Instead of continuously trying to see if the other person deploy is finish or not. And maybe even then put my deploy in a que if there is anothe...
Guest about 1 year ago in Application Server / Development 1

New System Tag to receive external commands to Reset the connection on specific devices

Adding an external PLC channel reset System Tag feature would significantly improve operational reliability. This capability is particularly important in scenarios such as PLC reboots, communication interruptions, or network-related outages, where...
Marcel Lima 7 months ago in Device Integration 0

Add filter and sort options in the Cross References screen

Being able to filter and sort in the Cross References screen of the object properties would make it substantially easier to have an overview of certain attribute usages. Right now you cannot group the references by attribute for example, which mak...
Bob Eeckhout over 1 year ago in Application Server / IDE 0