To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 470 of 470

Make a connection to a PLC without starting Citect

Often connecting to a PLC can be painful. Any change needs to be compiled, Citect restarted, and then you can test the connection. It would be very handy to have a tool in the Citect Studio that lets you play with parameters, IP addresses, a varia...
Guest about 4 years ago in Plant SCADA / API & Connectivity / Development Tools 1 Future Consideration

Driver Statistics

It would be nice have a Cicode interface that would allow engineers to query driver statistics. For example, group poll times from an abclx device.
Guest over 2 years ago in Plant SCADA / Drivers / Protocols 4 Future Consideration

Add {equipment.ItemName} to reference objects in Equipment Editor

When working with a PLC that uses name based tags, such as Rockwell Control Logix 5000 series, creating equipment results in repetitive typing or copy and pasting which is not only time consuming, but adds possible user error when entering tags. F...
Guest over 2 years ago in Plant SCADA / Development Tools / Equipment 1

Event Type Trends shows last good value during communication failure

*Form last 3 to 4 years we have been selling and proposing Citect Scada with DNPr driver in Pharmaceutical Companies as a 21CFR compiled Solution. We are using the back-filling feature of DNPr driver with Citect Scada. To use this feature we confi...
Guest almost 4 years ago in Plant SCADA / Alarms 0 Future Consideration

BACnet Object Type Trend not supported

A customer who relies on the BACnet driver have found that the absence of a standard Object Type Trend is a significant limitation to their project. We would greatly appreciate your consideration of this enhancement request, and we look forward...
Peter Chung about 1 year ago in Plant SCADA / Drivers / Protocols 1 Future Consideration

SOE Filter functions -SA Project template

The default SA Project template, comes with SOE list where system alarms and states are defaulted to be shown independent of any filter applied. From what I see this comes form the FUNCTION _AlarmPage_UpdateFilter() being set with "OR StateNumeric...
Guest over 2 years ago in Plant SCADA / Historic Data / Storage 0

Deployment supporting Terminal Server and Profiles

Deployment is not officially and 100% supporting Terminal Server systems. Supporting this by the Deployment Server and also the possibility to select a Profile for the Terminal Server and not is needed.
Guest about 4 years ago in Plant SCADA / Development Tools 1 Future Consideration

Find user function from Plant SCADA Studio

Add an extra search option in the Find & Replace option in the Studio. The Project Editor used to have this option.
Guest over 1 year ago in Plant SCADA / Development Tools 2

A function to get the number of display clients connected to a server process

Existing ServerInfoEx() function gives the number of server side Trans of a specified service type but there is no way to get the number of display clients connected to a server.
Guest about 4 years ago in Plant SCADA / Other 0 Future Consideration

Ability to send historical field data to Historical for previous hour

The original enhancement request is in the attached document.
Guest 3 months ago in Enterprise SCADA Server 2 Reviewing