To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 791

Convert Raw Tag to Custom

Currently it is possible to convert a Custom Tag to Raw Tag, but not vice versa. This would be v helpful when migrating controllers.
Geoff Lewis over 2 years ago in APC / General 0 Evaluating

Mitsubishi FX5U PLC driver for Plant SCADA

MELSECQ protocol can be used to communicate with FX5U, but the addressing system is different. MELSECQ expects Hexadecimal addressing while FX5U expects Octal addressing system.
Jiri Rysavik over 1 year ago in Device Integration 0

Use TagInfoEx() to check whether an alarm exists

If you have an equipment type with an item and this creates a variable tag and an alarmtag you could use the TagInfoEx() function to check whether this item has an alarm defined. Let me give an example: Equipment:Motors.M1 Item:Run Variable Tag Na...
Guest over 2 years ago in Plant SCADA / Equipment 0

How to communicate between Plant SCADA and OMRON PLC NJ series

Among Korean Plant SCADA users, there are often users who use Omron NJ series PLC. They express great inconvenience and dissatisfaction about the lack of communication between Plant SCADA and Omron NJ PLC. The method of changing the address of KB0...
Guest over 1 year ago in Device Integration 0

Create new Trend Type that hooks into Variable Tag Subscriptions

Traditional periodic Trend type makes the end user set a very small sample time such that no sample is missed. This is a complete mis-match between what is happening at the tag level. I propose a new Trend type that hooks into the Tag Subscription...
Guest over 5 years ago in Plant SCADA / Alarms 3 Unlikely to implement

prescriptive actions as task list

Prescriptive actions are very relevant and frequently hard to read as displayed in 2 row text field. It would be great if this can be displayed as a clear task list with the possibility to expose also on APIs so it can be leveraged by other soluti...
Luca Bruni almost 3 years ago in Predictive Analytics / Web Monitoring Client 1 Planned

Simple "model health" summary graphic showing status of all individual residuals within a model

Per the attached image, create a summary graphic to show the health of all tags within a model. This provides a simple "at a glance" view of the health of all underlying tags within a model, and can quickly highlight the tags that are contributing...
Guest about 4 years ago in Predictive Analytics / Web Monitoring Client 0 Future consideration

Historian Point Administration Enhancements

From Alex Jenkins, 2020-04-06 Add search/filter for a specific point (had to scroll through alphabetically). It was ok since I was only looking for 6 points to update, but if there were a lot, this could be tedious. Be able to select only certain ...
Christian-Marc Pouyez over 5 years ago in Predictive Analytics / Model Builder Client 1 Planned

Prediction Mode (Open Loop)

Provide a "prediction mode" for the controller where it can read the values from the DCS and predict the steady state values of the CVs but it cannot write back the setpoints to PID controller in DCS. Read-only connectivity to the DCS, moves are c...
Ina Llewellyn almost 3 years ago in APC / Connectivity 1 In development

Make LogViewer File->Open default to folder of currently open log file

Big Picture User Experience Make LogViewer File->Open default to folder of currently open log file Detailed Description Currently, when a user opens a log file, and then attempts to open another log file, the file->open dialog box always def...
Jake Hawkes over 1 year ago in Enterprise SCADA Server 0 Reviewing