Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Enterprise SCADA Server

Showing 115 of 774

Improvements to OPC Client

Enhance the OPC Client such that it can handle third-party OPC Servers that present 10,000+ points as one remote. This "idea" relates to GCS ticket # 960321526.
Craig Parkin about 2 years ago in Enterprise SCADA Server / Protocols and Commlines 1 Waiting for information

flowTotalConfig integration blocks replication enhancement request

Our customer has a business need to be able to manually adjust previous hour/day/month etc of a flowTotal record. So that it provides accurate information in the control room so that GCN records can be met and gas used can be properly tracked.Ofte...
Vitali Unke about 1 year ago in Enterprise SCADA Server 0

[WWW] Auto-Logon and Logoff - Is there an AVEVA-recommended solution?

Our customer, City of Calgary Water Services, will be upgrading from 7.7 to ES2023 or ES2024. They presently have some batch files in place to automatically log an operator off after a certain length of time and then automatically log in a Read-On...
Serge LeBlanc over 2 years ago in Enterprise SCADA Server / Control Room Management / Security and DMZ 2 Already exists

Enhance Re-alarming application for any alarm severity

Big Picture User Experience Enable Re-Alarming application to re-alarm alarms of any severity that were acknowledged by SCADA controller Detailed Description Background Re-Alarming application designed to re-annunciate alarms that are previously w...
Guest over 2 years ago in Enterprise SCADA Server / Alarms 1 Future consideration

ADE find/replace case sensitivity

Summary In 7.6, the Find was insensitive but the Replace was sensitive. This resulted in fewer rows being modified than what was found in the Find. In other words, it was a hidden defect. Making Find and Replace consistent was important to ensure ...
Josie Liu over 2 years ago in Enterprise SCADA Server / ADE / PnT / MoC 2 Will not implement

Add 'Workstation Administrator' Role to Active Directory

Big Picture User Experience Following the Principle of Least Privilege, AD-Tiering and now Enterprise Access Model , add 'Workstation Administrator' Role to Active Directory to enable a separation of duties between server administrators and deskto...
Julian Reyes Riveros over 2 years ago in Enterprise SCADA Server / Security and DMZ 0 Planned

[Test & DOC] Ability to configure datapump to pull data from an untrusted domain

Big Picture User Experience Officially test and document the feature added to datapump in OASyS 7.6R4 to allow pulling from an untrusted, lower security zone. Detailed Description Customer wants to datapump data from an untrusted domain into a tru...
Tyson Burr over 2 years ago in Enterprise SCADA Server / Administration / Installation / Datapump / Documentation 0 Future consideration

MoC Extensions Disabled by Default

As a system integrator I would prefer to see MoC extensions disabled by default, to be enabled if needed, in order to remove this from the required lists of tasks to be executed for a system installation having MoC.
Tyson Burr over 1 year ago in Enterprise SCADA Server 0

Make LogViewer File->Open default to folder of currently open log file

Big Picture User Experience Make LogViewer File->Open default to folder of currently open log file Detailed Description Currently, when a user opens a log file, and then attempts to open another log file, the file->open dialog box always def...
Jake Hawkes over 1 year ago in Enterprise SCADA Server 0 Reviewing

IEC-104

IEC60870-101 or IEC60870-104 are the serial and IP versions of what is sometimes refered to IEC-104. These are both part of the IEC60870-5 standard, whereas ICCP is IEC60870-6, and is different. IEC_62351 is a standard for securing the various pro...
Josie Liu over 5 years ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines / Telemetry 0 Reviewing