Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Add Ctrl+W as keyboard shortcut for closing window in Graphics Builder.

Standard windows behavior for Ctrl+W should be supported by all windows application in my opinion.
Guest over 3 years ago in Plant SCADA / Development Tools 0 Reviewed & Categorized

XREF IMS 3609692 : Enhancement Request - Allowing pasting images into ITAA OMI web widget EO.

XREF IMS 3609692 When trying to paste images inside web widget application inside ITAA session , it dos not work and only possible to paste text. Here are the details: OMI Intouch Version: 23.0.001 ITAA Version: 23.0.00 or 2023b (Replicated on bot...
Ragaei Mahmoud Abdel Maksoud Mohamed over 1 year ago in Application Server / OMI desktop runtime 0

Column/row-wise adding or deleting of models

When creating a Composite Model, allow models to be selected or deselected by row or column. Currently possible only individually or all together.
Geoff Lewis over 3 years ago in APC / Model Identification 0 Evaluating

Define Controller Watchdog Tags

allow them to be selected from a List, avoid the potential for typos and other errors.
Geoff Lewis over 3 years ago in APC / Controller Configuration 0 Evaluating

Define DCS Readback and DCS Status

When defining these tags in a controller, allow them to be selected from a list of all Input Tags, with possibility to apply a filter to limit the size of the presented list. Currently we have to enter the text directly with all kinds of possibili...
Geoff Lewis over 3 years ago in APC / Controller Configuration 0 Evaluating

Convert Raw Tag to Custom

Currently it is possible to convert a Custom Tag to Raw Tag, but not vice versa. This would be v helpful when migrating controllers.
Geoff Lewis over 3 years ago in APC / General 0 Evaluating

Use TagInfoEx() to check whether an alarm exists

If you have an equipment type with an item and this creates a variable tag and an alarmtag you could use the TagInfoEx() function to check whether this item has an alarm defined. Let me give an example: Equipment:Motors.M1 Item:Run Variable Tag Na...
Guest over 3 years ago in Plant SCADA / Equipment 0 Reviewed & Categorized

Increase FlowTotalConfig totalblocks from 4 to 6

Increase the total blocks from 4 to 6 (1 additional as a spare)to enable additional elements to be calculated within one flowTotalConfig Flow Rate [0]Current Hour Accum [1]Previous Hour Accum [2]Current Day Accum [3]Current Month Accum [4]
Vitali Unke over 1 year ago in Enterprise SCADA Server 0 Future consideration

Higher Visibility for Datapump Issues

Request that there be a better way to tell when Datapump is not pumping.
John Bjartveit over 1 year ago in Enterprise SCADA Server / Datapump 0

Paste a copied object on the same coordinates as the original object

When pasting a copied object, it would be nice to have the option to paste it at the same coordinates of the copied/original object. Sure, I can note the coordinates using "Adjust Position and Size" and then enter the coordinates on the new obj...
Peter Chung over 3 years ago in Plant SCADA / Graphics / Visualization 0 Reviewed & Categorized