To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Enterprise SCADA Server

Showing 116 of 775

Alternate timeseries hourly averaging algorithm

Enhancement request to either allow integrators to modify timeseries averaging algorithm or provide hooks to allow integrator to modify the operation. We implemented an alternative timeseries averaging algorithm on many installations. Prior to bin...
Guest almost 4 years ago in Enterprise SCADA Server / Historical / Realtime API/SDK 1

Expansion of point description field string length

SE PA WWW previously modified database schema and structure now with binary release modifications tot he database structure are limited. Support for modifying existing types including changing string length is not supported. SE PA WWW typically...
Guest almost 4 years ago in Enterprise SCADA Server / Realtime Schema 3 Will not implement

NMC should not log confusing messages if the ADLDS Cross Domain Replication sender is also a receiver from another ADLDS realm

The current 2023 system designs being provided to customers include an es/deployment system with it's own ADLDS realm. AOR area/group changes are made there first and it is the global table owner for its realm. The primary production system is set...
Hugh Arai almost 2 years ago in Enterprise SCADA Server / Administration / Installation / Replication 0 Reviewing

Support OS live upgradability

Big Picture Support live OS upgradability after Enterprise SCADA has been upgraded to v2023, without the need for a cold start. Detailed Description It is currently assumed that it will be required to update the OS from one major version to the ne...
Jake Hawkes about 2 years ago in Enterprise SCADA Server / Administration / Installation / Architecture 0 Reviewing

Load New BLTs without Restart or Failover

No description provided
Guest about 2 years ago in Enterprise SCADA Server 0 Reviewing

Multi-system support for HMI

User Story As a pipeline operator / supervisor monitoring pipeline assets that span multiple RealTime environments, I would like to be able to connect my HMI to the combined multi-RealTime environment, conferring all benefit of functionality co...
Tyson Burr over 4 years ago in Enterprise SCADA Server / Architecture / Control Room Management 1 Future consideration

Address nuisance error log messages related to the Trend BLT

Detailed Description Request that the Recordset open error be moved to ALWAYS as it does provide insight into an issue with trending a point 2022-05-16 12:18:36.744 [TID=0x299c] WARNING: Trend: numCollects: Recordset open (execute) failed [-214721...
Serge LeBlanc about 2 years ago in Enterprise SCADA Server / Administration / Installation 1 Future consideration

Request disabling NetBios be validated

This request created created from a Pembins 2018 SP3 inquiry but I believe it has been agreed to only be considered for supported versions or future release. Previous IMS from ConEd - 2178824 was closed stating, "noting they need to validate the c...
Serge LeBlanc over 2 years ago in Enterprise SCADA Server / Administration / Installation / Architecture / Security and DMZ 1 Planned

Enhance Device Rollup to support subdevices from multiple datasets

Big Picture User Experience Enhance device rollup from subdevices (telemetered and device object) that belong to datasets that differ from the parent device (top-level device) object dataset. Background With large systems it is now very common to ...
Guest over 2 years ago in Enterprise SCADA Server / Alarms / Control Room Management 0 Reviewing

GroupArea in the area table only contains the first 20 groups

Do we actually have a limit of 20 groups per area? Some testing has shown that one can add more then 20 groups into an area. The GroupAreaJoin table populates all of them correctly however the "group[0-19].name” array-field in the area table only ...
Bradley Tomanik over 2 years ago in Enterprise SCADA Server / Administration / Installation / Realtime 1 Already exists