Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Telemetry

Showing 12

Dnaswana with DALPrompter

Dnaswana needs the ability to be run on a system that has no RealTime server. For example, GRT project uses support computers on RDS systems (with no Realtime services on there) and needs to run dnaswana from those computers and get traffic data f...
Vitali Unke over 1 year ago in Enterprise SCADA Server / Architecture / Omnicomm / Security and DMZ 0

Update SNMP protocol to support v3

Big Picture User Experience Support v3 of the SNMP protocol Detailed Description TBD: any particular SNMP v3 features?
Randy Kostiuk about 2 years ago in Enterprise SCADA Server / Protocols and Commlines 6 Future consideration

Enhancements to use Device DataQuality: uncertain and error

We request enhancements to the ability for a protocol to indicate data quality to the krunch routines, as first requested in OASYS-518 (API for Protocols to indicate data to be krunched is questionable according to field device): https://aveva.aha...
Collin Heggerud about 1 year ago in Enterprise SCADA Server / Krunch and Data Manipulation / Realtime API/SDK 0

Allow protocol specific extensibility of dnlist ADE Form

The dnlist ADE form has protocol specifics built in for BSAP and Fisher ROC but does not allow any extensibility so it is difficult to add "Download by List" functionality to a new protocol (such as DNP3).
Collin Heggerud about 1 year ago in Enterprise SCADA Server / ADE / PnT / MoC / Protocols and Commlines / Telemetry 1 Will not implement

Request for a new telemetered point type/table

SE PA WWW integrator has industry specific telemetered point type of Water Reservoir. Reservoirs are a type of telemetered point similar to an analog but with additional calculations for volume etc. Prior to binary release integrator modified the ...
Guest over 3 years ago in Enterprise SCADA Server / Realtime API/SDK / Realtime Schema / Telemetry 1

IEC-104

IEC60870-101 or IEC60870-104 are the serial and IP versions of what is sometimes refered to IEC-104. These are both part of the IEC60870-5 standard, whereas ICCP is IEC60870-6, and is different. IEC_62351 is a standard for securing the various pro...
Josie Liu over 5 years ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines / Telemetry 0 Reviewing

Enhance Omnicomm to make it easier for protocols to work with sub-remote status indicator.

An enhancement for protocol developers that is standard for all protocols.

Multiple transient state support for multistate command

Detailed Description Due to various physical factors, sometimes a 2-bit status point will transition through both the (valid) TRANSIT state as well as the (invalid) ERROR state, on its way from CLOSED to OPEN (or vice versa). This enhancement will...
Guest about 2 years ago in Enterprise SCADA Server / Alarms / Krunch and Data Manipulation 0 Reviewing

Request for year to be added to the runtime structure

We've previously added an additional "year" field to the runtime structure to track hours per year for a 7.5 project. I'd like to request an enhancement to OASyS 2021 to add "year" to the runtime structure please. I see that there's a runtimeyear....
Natalie Hunter over 3 years ago in Enterprise SCADA Server / Krunch and Data Manipulation / Realtime Schema 5 Will not implement

Offline Rate Integration

Customers on 7.5 system often had a small change made to vdb_rate.cpp, allowing integration to continue even when a point was not fresh, using its last good rate value. This allows calculated volume integrations to match more closely with what oth...
Jake Hawkes over 4 years ago in Enterprise SCADA Server / Krunch and Data Manipulation 0 Future consideration