To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 54 of 832

Update versions active x controls - Process Analyst , Database Exchange or add new ones.

Libraries of Active X haven't been updated in a long time, could use refreshing controls with the new times ;)Everything looks like from 20 years ago.Clients wants New Bargraphs, Gauges, Datapickers for Reports, Textbox, Tables, etc. Are there any...
Guest 9 days ago in Plant SCADA / Graphics / Visualization 0 Submitted

Graphics Builder - drawing graphics on layers

This makes drawing large synoptics much easier, because by turning off a given layer you can hide elements. Each object or graphic could have a layer number parameter in its properties. Currently, to apply this, we do it by embedding a genies into...
Guest 9 days ago in Plant SCADA / Graphics / Visualization 0 Submitted

Invalid Timestamp Handling in IEC 60870-5-104 Driver within AVEVA Telemetry Server

In an energy remote control system, we are using the AVEVA Telemetry Server to read/write data from PLCs via the IEC 60870-5-104 protocol. During analysis of the communication frames, we have observed that, in some cases, values are received with ...
Jordi Román 6 months ago in Device Integration 0

Remove the Need for pg* Files

Eliminate the requirement for pg*.dbf files. These files are not really needed as the same info is in the .ctg files. These files make it difficult to use PlantSCADA with version control, such as SVN or git since either these files need to be vers...
Will Herndon almost 4 years ago in Plant SCADA / Graphics / Visualization 1 Reviewed & Categorized

BACNET: Addressing objects via ObjectName

We have several requests for accessing BACNET objects via their "ObjectName", rather than their HW address ie: AI.1.PresentValue. There are 2 issues with the current way of addressing: Makes it difficult to make equipment Some PLC’s (ie Wago) shif...
Guest over 5 years ago in Device Integration 1

S7TCP support for firmware V3.0 with username and password

To increase security this option is available on the S7-1500 controller. Without a username and password anyone connected to the network can connect, browse and change values.
Guest almost 2 years ago in Device Integration 4

wwClient update/fix

Hi everybody, for convenient troubleshooting of SuiteLink communication with drivers, it would be useful to have an upgraded version of the wwClient utility, which right now doesn't support encrypted SL (making it useless many times in SMS environ...
Mattia Popolla 5 months ago in Device Integration 0

OPC UA Server - Restricting Client Access

Hi, My OEM customer currently uses TOP Server 6 instead of AVEVA OPC UA Server for different reasons. One of them is that it's possible in TOP Server 6 to have different users access different parts of the OPC UA Server via No Access, Read Only or...
Peter Rosenberger 10 months ago in Device Integration 1

MQTT

More and more devices support MQTT protocol
Ales B almost 6 years ago in Device Integration 5

BTL listing of Bacnet driver

We are getting a lot of feedback in the market about us not being BTL listed as a compliant B-AWS/ B-OWS. We see this being demanded in more and more tenders, so I was wondering if this is something you have looked at. The basic stuff for B-OWS se...
Guest over 5 years ago in Device Integration 1 Will not implement