Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Add more custom fields in equipment, variable tags, alarms

When using structures in plc and much addresses, we often use more custom fields. It would be useful to expand more than 8 custom fields.
Guest 28 days ago in Plant SCADA / Equipment 0 Submitted

BACNET: Addressing objects via ObjectName

We have several requests for accessing BACNET objects via their "ObjectName", rather than their HW address ie: AI.1.PresentValue. There are 2 issues with the current way of addressing: Makes it difficult to make equipment Some PLC’s (ie Wago) shif...
Guest over 6 years ago in Device Integration 1

New System Tag to receive external commands to Reset the connection on specific devices

Adding an external PLC channel reset System Tag feature would significantly improve operational reliability. This capability is particularly important in scenarios such as PLC reboots, communication interruptions, or network-related outages, where...
Marcel Lima 9 months ago in Device Integration 0

S7TCP support for firmware V3.0 with username and password

To increase security this option is available on the S7-1500 controller. Without a username and password anyone connected to the network can connect, browse and change values.
Guest over 2 years ago in Device Integration 4 Planned

Invalid Timestamp Handling in IEC 60870-5-104 Driver within AVEVA Telemetry Server

In an energy remote control system, we are using the AVEVA Telemetry Server to read/write data from PLCs via the IEC 60870-5-104 protocol. During analysis of the communication frames, we have observed that, in some cases, values are received with ...
Jordi Román about 1 year ago in Device Integration 0

Copy+Paste items inside Equipment editor

If we need to add an equal or similar item to several equipments we need to type everything, or if we have several tags in the same equipment and want to add an alarm to all of them, it should be useful to copy the alarm part from one item to othe...
Guest over 6 years ago in Plant SCADA / Development Tools / Equipment 1 Future Consideration

Unify automatic generation of Configuration Parameters in Plant SCADA Studio 2023 and Equipment Editor

Currently when adding new Equipment through Equipment Editor, all relevant Configuration Parameters will be generated automatically and are available in Plant SCADA Studio 2023. However if you add a new Equipment in Plant SCADA Studio and run "Upd...
Guest almost 4 years ago in Plant SCADA / Equipment 1 Reviewed & Categorized

MQTT

More and more devices support MQTT protocol
Ales B over 6 years ago in Device Integration 5

BTL listing of Bacnet driver

We are getting a lot of feedback in the market about us not being BTL listed as a compliant B-AWS/ B-OWS. We see this being demanded in more and more tenders, so I was wondering if this is something you have looked at. The basic stuff for B-OWS se...
Guest about 6 years ago in Device Integration 1 Will not implement

Speed Up Equipment Update

Anyone who has to rename/edit equipment in Studio
Guest about 1 year ago in Plant SCADA / Equipment 1 Future Consideration