To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 32 of 791

Remove the Need for pg* Files

Eliminate the requirement for pg*.dbf files. These files are not really needed as the same info is in the .ctg files. These files make it difficult to use PlantSCADA with version control, such as SVN or git since either these files need to be vers...
Will Herndon over 3 years ago in Plant SCADA / Graphics / Visualization 1

Modify the S7TCP driver to support S7 PLCSIM Advanced

Modify the S7TCP driver to support S7 PLCSIM Advanced
Peter Holmberg 11 months ago in Plant SCADA / Drivers / Protocols 0 Submitted

OPCUA Variable Import limited to 79 characters

When you import Variable Tags from an OPCUA Server the tag names are truncated to 79 characters, this is sometime not enough. Duplicate tagnames are not allowed. You have to manually adjust all the names. For instance when you connect to a Plant S...
Guest over 2 years ago in Plant SCADA / Drivers / Protocols 1

Native UMAS driver for Modicon PACs

Word is out that active OFS development has stopped. OFS is the current high-performance driver for all Schneider Electric / Modicon PLCs, using its proprietary UMAS protocol. Communication using UMAS and OFS has many advantages over standard Modb...
Guest 12 months ago in Plant SCADA / Drivers / Protocols 0 Unlikely to implement

Add ability to lock guidelines in Graphics Builder (so they dont change when you accidentally click them)

The problem is: in the graphics builder the guidelines can be clicked or dragged using the mouse, and then they change! Whilst dragging is quite a conscious action, clicking something is easily done accidentally. You are not warned that you clicke...
Guest about 4 years ago in Plant SCADA / Graphics / Visualization 1 Unlikely to implement

Bundle UA Server Expert Instead of OFS with PlantSCADA

OFS is bundled with Citect so it can be installed on the same machine and use the Citect license. But it just feels wrong introducing an OPC DA server when Schneider now have the UA server expert. My idea would be to bundle UA Server Expert with P...
Guest 12 months ago in Plant SCADA / Drivers / Protocols 1 Future Consideration

Add 64-bit INT to Modbus Driver

Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Guest over 2 years ago in Plant SCADA / Drivers / Protocols 1

Enhance the OPC UA server browsing feature in AVEVA Plant SCADA to allow batch selection and import of multiple tags simultaneously, improving efficiency for users handling large tag sets

The current OPC UA server browsing feature in AVEVA Plant SCADA only allows users to browse and import tags one by one. This process is not feasible when dealing with large systems containing thousands of tags, as it significantly increases the ti...
Guest over 1 year ago in Plant SCADA / Drivers / Protocols 0 In Roadmap

Better keyboard support in Graphics Builder

A lot of potential Graphics Builder tasks can be repetitive, and can be sped up using a keyboard instead of a mouse. But some dialogues are not keyboard friendly. The specific case I have in mind is Tools -> Swap Colours. Opening it from the ke...
Mark Rogers almost 2 years ago in Plant SCADA / Graphics / Visualization 1

Fontsize ciode form functions

The posibility to change the fontsize, font used in the cicode form functions.