To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 54 of 776

BACNET: Addressing objects via ObjectName

We have several requests for accessing BACNET objects via their "ObjectName", rather than their HW address ie: AI.1.PresentValue. There are 2 issues with the current way of addressing: Makes it difficult to make equipment Some PLC’s (ie Wago) shif...
Guest over 5 years ago in Device Integration 1

S7TCP support for firmware V3.0 with username and password

To increase security this option is available on the S7-1500 controller. Without a username and password anyone connected to the network can connect, browse and change values.
Guest over 1 year ago in Device Integration 4

Copy+Paste items inside Equipment editor

If we need to add an equal or similar item to several equipments we need to type everything, or if we have several tags in the same equipment and want to add an alarm to all of them, it should be useful to copy the alarm part from one item to othe...
Guest over 5 years ago in Plant SCADA / Development Tools / Equipment 1 Future Consideration

Improvements of the deployment functionality

Deploying a project can be slow, especially upoading a new version of the project. A progression bar with remaining time would be nice. Would be a nice feature if you could upload the complete project including the configuration files. Have an opt...
Guest almost 3 years ago in Plant SCADA / Development Tools 5

BTL listing of Bacnet driver

We are getting a lot of feedback in the market about us not being BTL listed as a compliant B-AWS/ B-OWS. We see this being demanded in more and more tenders, so I was wondering if this is something you have looked at. The basic stuff for B-OWS se...
Guest about 5 years ago in Device Integration 1 Will not implement

MQTT

More and more devices support MQTT protocol
Ales B over 5 years ago in Device Integration 5

Faster compiler

The old compiler needs to utilize modern hardware better to decrease compile-time. Also applies to other tools who I suspect uses same/similar routines working with DBFs and such. Like page update and packing, etc.
Guest over 2 years ago in Plant SCADA / Development Tools 0 Future Consideration

Possibility to modify values directly in the SIM OI-Server

For testeing purposes, the OI-Server SIM can be handy. The only missing thing here is the possibility to modify values directly through the UI of it. I now use the WWClient to do this to get the values I want in my Galaxy environment. A added valu...
Lauran Lint 10 months ago in Device Integration 0

Upgrade the MAXIMUM LENGHT for STRING and CITECT.INI Parameters over 254 characters !

As discussed in TN000028481 , the MAXIMUM LENGHT for STRING and CITECT.INI Parameters is 254 characters ! This cause many problems inside CICODE SCRIPTS (this limit is too strong in modern world!) and in [Event] parts of citect.ini (you must reduc...
Guest over 2 years ago in Plant SCADA / Development Tools 0

Call Excel Addin functions from vba

Whe have our own Excel macro's for generating tags, alarm, trends, etc and would like to use the 64bit version of Excel. We want to open a DBF using the Excel Addin, run our own macro and then save the DBF file using vba.
Guest over 1 year ago in Plant SCADA / Development Tools 1 Future Consideration