To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Expand Alarm generation

Expand alarm generation. Add 10 user defined fields for each alarm so that the user can save alarm-related information
Guest about 2 years ago in Application Server / Alarming 2

BACNET: Addressing objects via ObjectName

We have several requests for accessing BACNET objects via their "ObjectName", rather than their HW address ie: AI.1.PresentValue. There are 2 issues with the current way of addressing: Makes it difficult to make equipment Some PLC’s (ie Wago) shif...
Guest over 6 years ago in Device Integration 1

Increase Uptime by Retrieving License Statuses for Alarming in OMI/WIN-911 from SP

The System Monitor has a rule category called "License Server Alerts". This allows the monitor to catch; "Alert on licenses that expire within X day(s)", for example. Additionally, through the rule category named "SMC Logger (Filter)" it is possib...
Jørgen Myklebust over 1 year ago in Application Server / Alarming 2

New System Tag to receive external commands to Reset the connection on specific devices

Adding an external PLC channel reset System Tag feature would significantly improve operational reliability. This capability is particularly important in scenarios such as PLC reboots, communication interruptions, or network-related outages, where...
Marcel Lima 9 months ago in Device Integration 0

S7TCP support for firmware V3.0 with username and password

To increase security this option is available on the S7-1500 controller. Without a username and password anyone connected to the network can connect, browse and change values.
Guest over 2 years ago in Device Integration 4 Planned

Invalid Timestamp Handling in IEC 60870-5-104 Driver within AVEVA Telemetry Server

In an energy remote control system, we are using the AVEVA Telemetry Server to read/write data from PLCs via the IEC 60870-5-104 protocol. During analysis of the communication frames, we have observed that, in some cases, values are received with ...
Jordi Román about 1 year ago in Device Integration 0

MQTT

More and more devices support MQTT protocol
Ales B over 6 years ago in Device Integration 5

BTL listing of Bacnet driver

We are getting a lot of feedback in the market about us not being BTL listed as a compliant B-AWS/ B-OWS. We see this being demanded in more and more tenders, so I was wondering if this is something you have looked at. The basic stuff for B-OWS se...
Guest about 6 years ago in Device Integration 1 Will not implement

Ability to Ack all alarms on object and area

The ability to ack all alarms on an object, whether it's a user defined or a area object with a built in method.
Ernst Van Wyk 6 months ago in Application Server / Alarming / Application Server Runtime 0

Custom alarm severities

Our need is to have more than just 4 alarm severities / criticities. It will allow better alarm management with more than 4 colors, severity...
Florent Michelfelder about 2 years ago in Application Server / Alarming 0