Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 120 of 776

Include the Tank functionality in the baseline portion of the product

The Tank table is tied to the LMS apps and does not get exposed on a baseline system where some customers could benefit from its built in nature. Allowing a customer to use the Tank table (and the new FlexTank object) as opposed to a custom reserv...
Guest 7 days ago in Enterprise SCADA Server / Applications 1

Improve the warning/alarm message of the Admin Pager for low Physical Memory threshold

The default wmimonitor alarm message reports "freespace" is below warning\alarm limit for both low physical memory and logical disk. Requesting the messages are updated to be more clear which resource is affected by changing the physical memory me...
Vitali Unke 13 days ago in Enterprise SCADA Server / Alarms 0

Python scripting in system platform

it would be great adding Python scripting to system platform making it easy and flexible to leverage the power of python
Guest about 1 year ago in Application Server / Scripting 3 Planned

Industrial Graphic script editor should ask for saving on Exit after ESC key press

When writing some scripts in Industrial Graphic editor, if we press ESC key by mistake, it closes, no matter if there was a script modified or written without asking for saving or not. So instead using Script editor i always write script in Notepa...
Marcin Wozniczka 6 months ago in Application Server / Scripting 2

Need a replacement for PrintScreen() function that works in OMI

OMI is missing a way to programmatically print to printer. Like the PrintScreen function in InTouch. Should be able to print the whole application or only part of it, i.e. a popup window.Ref: IMS#2206203
Øyvind Hansen 3 months ago in Application Server / Scripting 1

Get Custom Property Reference by script

Allow retrieving a reference from a custom property to reuse it in a graphic. Example: indicate to the user the attribute used in a display and be able to find it in Historian.
Hugues Alexis 9 months ago in Application Server / Scripting 0

SPS version 11 support for RTUPlayer and Trainer.

Requesting support for SPS 11.1 and Windows Server 2022 operating system for RTU Player and Trainer applications.
Andrew Potkins 2 months ago in Enterprise SCADA Server / Applications 0

Allow the "safety string" to be moved or disabled in the alarm message

Currently in baseline, (SAFETY) is always added as a prefix to Safety Related alarm messages. It is used as the marker whether the alarm should be recorded in the event table as safety-related. Our customer wants to have (SAFETY) as a suffix for t...
Hugh Arai 2 months ago in Enterprise SCADA Server / Alarms 0

Omnicomm should better support modern network speeds

Omnicomm has a feature that allows it to wait longer for large messages than for short messages. This feature defaults to calculations based on messages transmitted at 1200bps and has a maximum configurable rate of 38400bps. In a world where many ...
Collin Heggerud 2 months ago in Enterprise SCADA Server / Omnicomm 0

Omnicomm retries on temporary connections should retry the connection

On Tech Support case 962469169 it became very clear that when the socket of a temporary connection was broken, Omnicomm would not re-attempt the connection until the next scheduled poll interval (e.g., 5 minutes later). I would expect that if Omni...
Collin Heggerud 2 months ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines 0