To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 123 of 776

Include the Tank functionality in the baseline portion of the product

The Tank table is tied to the LMS apps and does not get exposed on a baseline system where some customers could benefit from its built in nature. Allowing a customer to use the Tank table (and the new FlexTank object) as opposed to a custom reserv...
Guest 7 days ago in Enterprise SCADA Server / Applications 1

Improve the warning/alarm message of the Admin Pager for low Physical Memory threshold

The default wmimonitor alarm message reports "freespace" is below warning\alarm limit for both low physical memory and logical disk. Requesting the messages are updated to be more clear which resource is affected by changing the physical memory me...
Vitali Unke 13 days ago in Enterprise SCADA Server / Alarms 0

Invalid Timestamp Handling in IEC 60870-5-104 Driver within AVEVA Telemetry Server

In an energy remote control system, we are using the AVEVA Telemetry Server to read/write data from PLCs via the IEC 60870-5-104 protocol. During analysis of the communication frames, we have observed that, in some cases, values are received with ...
Jordi Román 3 months ago in Application Server / Device Integration / Other 0

Expand Auto-binding capabilities

Auto-binding has the potential to improve productivity significantly by removing the need for complex IO referencing scripts as well as allowing users to test IO assignment in runtime. Auto-binding today can only use the assigned IO device and Sca...
Ernst Van Wyk over 1 year ago in Application Server / Device Integration / IDE 1

Act as a REST/ WEB API server

Act as a REST API Server like the GR Access Tool for better integration with other products. GR Access Toolkit SDK needs to be written in .NET where REST API supports multiple programming languages.
Rainer Dsouza 7 months ago in Application Server / Device Integration 1

Create the DT suffix for the OI gateway to support the Date_And_Time data type from Siemens PLC in OPCUA

The DT suffix was present in the SIDirect communication driver and is now disappear in the OIGateway. This suffix permit to translate directly the data type Date_and_Time from the PLC and to the PLC with the object in the application server withou...
Guest 4 months ago in Application Server / Device Integration 0

OPC UA Server - Restricting Client Access

Hi, My OEM customer currently uses TOP Server 6 instead of AVEVA OPC UA Server for different reasons. One of them is that it's possible in TOP Server 6 to have different users access different parts of the OPC UA Server via No Access, Read Only or...
Peter Rosenberger 7 months ago in Application Server / Device Integration 1

SPS version 11 support for RTUPlayer and Trainer.

Requesting support for SPS 11.1 and Windows Server 2022 operating system for RTU Player and Trainer applications.
Andrew Potkins 2 months ago in Enterprise SCADA Server / Applications 0

Allow the "safety string" to be moved or disabled in the alarm message

Currently in baseline, (SAFETY) is always added as a prefix to Safety Related alarm messages. It is used as the marker whether the alarm should be recorded in the event table as safety-related. Our customer wants to have (SAFETY) as a suffix for t...
Hugh Arai 2 months ago in Enterprise SCADA Server / Alarms 0

Omnicomm should better support modern network speeds

Omnicomm has a feature that allows it to wait longer for large messages than for short messages. This feature defaults to calculations based on messages transmitted at 1200bps and has a maximum configurable rate of 38400bps. In a world where many ...