Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 12 of 791

Omnicomm should better support modern network speeds

Omnicomm has a feature that allows it to wait longer for large messages than for short messages. This feature defaults to calculations based on messages transmitted at 1200bps and has a maximum configurable rate of 38400bps. In a world where many ...
Collin Heggerud 3 months ago in Enterprise SCADA Server / Omnicomm 0

Omnicomm retries on temporary connections should retry the connection

On Tech Support case 962469169 it became very clear that when the socket of a temporary connection was broken, Omnicomm would not re-attempt the connection until the next scheduled poll interval (e.g., 5 minutes later). I would expect that if Omni...
Collin Heggerud 3 months ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines 0

Improve calculation for availability for long running downtime record

In the customer project, there has been a long running downtime. For the metrics records, during the current shift period, the availability which should be 0 (since there is an active long downtime record) shows a value greater than 0. After the p...
Nina NICHOLLS about 1 year ago in Production Management (AMPLA MES) / Downtime 0 Future consideration

Dnaswana with DALPrompter

Big Picture User Experience Enable SCADA Administrator to use a centralized server to monitor and troubleshoot communications on multiple systems. Detailed Description To enhance security and reduce server resources, customers typically install mo...
Vitali Unke almost 2 years ago in Enterprise SCADA Server / Architecture / Omnicomm / Security and DMZ 0 Reviewing

Add ability for Omnicomm to support secure connections to devices

Enterprise SCADA desires to be at the forefront of security. Many protocols are beginning to support SSL/TLS connections to the end device, thus finally protecting that last few feet of communications from the networking equipment to the device. F...
Collin Heggerud almost 2 years ago in Enterprise SCADA Server / API / SDK / Developer Relations / Omnicomm / Protocols and Commlines / Security and DMZ 7 Reviewing

Update Duration for manual downtimes

In Ampla, duration is automatically updated only for open downtimes captured by Ampla (automatic). Manual open downtime durations are not updated automatically. Usually, a code item has to be written to update the duration of manual downtimes. Ref...
Priyanka VINAYCHANDER about 6 years ago in Production Management (AMPLA MES) / Downtime 0 Future consideration

IEC-104

IEC60870-101 or IEC60870-104 are the serial and IP versions of what is sometimes refered to IEC-104. These are both part of the IEC60870-5 standard, whereas ICCP is IEC60870-6, and is different. IEC_62351 is a standard for securing the various pro...
Josie Liu almost 6 years ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines / Telemetry 0 Reviewing

Enhance Omnicomm to make it easier for protocols to work with sub-remote status indicator.

An enhancement for protocol developers that is standard for all protocols.

Overlapping downtime events

We have request from both Alrosa and Polyus to allow for some mechanism to identify downtime records which overlap. Currently you can have overlapping records for manual records.
Mehrnoosh KHODAVERDY almost 6 years ago in Production Management (AMPLA MES) / Downtime 0 Future consideration

Access to Ampla Downtime Configuration via webservices

[Enhancement Request]Customer would like the ability to extract Downtime RP related configuration information through Ampla Web Services/CLR. Currently, Delay Accountants contact the Ampla Maintenance Group to get this information where the mainte...
Nina NICHOLLS about 6 years ago in Production Management (AMPLA MES) / Configuration / Downtime / Web API 0 Future consideration