Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 36 of 791

Allow protocol specific extensibility of dnlist ADE Form

The dnlist ADE form has protocol specifics built in for BSAP and Fisher ROC but does not allow any extensibility so it is difficult to add "Download by List" functionality to a new protocol (such as DNP3).
Collin Heggerud over 1 year ago in Enterprise SCADA Server / ADE / PnT / MoC / Protocols and Commlines / Telemetry 1 Will not implement

Enhance Omnicomm to make it easier for protocols to work with sub-remote status indicator.

An enhancement for protocol developers that is standard for all protocols.

Multiple transient state support for multistate command

Detailed Description Due to various physical factors, sometimes a 2-bit status point will transition through both the (valid) TRANSIT state as well as the (invalid) ERROR state, on its way from CLOSED to OPEN (or vice versa). This enhancement will...
Guest over 2 years ago in Enterprise SCADA Server / Alarms / Krunch and Data Manipulation 2 Reviewing

Y2K38 Preparedness

Big Picture User Experience The Year 2038 problem (also known as Y2038, or Y2K38, or the ‘Epochalypse’) is a time datatype bug involving the use a signed 32-bit integer to store of Unix time. The data type is only capable of representing integers ...
Jake Hawkes almost 3 years ago in Enterprise SCADA Server / Architecture / Krunch and Data Manipulation / Protocols and Commlines / Realtime / Realtime API/SDK 0 Reviewing

Request for year to be added to the runtime structure

We've previously added an additional "year" field to the runtime structure to track hours per year for a 7.5 project. I'd like to request an enhancement to OASyS 2021 to add "year" to the runtime structure please. I see that there's a runtimeyear....
Natalie Hunter almost 4 years ago in Enterprise SCADA Server / Krunch and Data Manipulation / Realtime Schema 5 Will not implement

Offline Rate Integration

Customers on 7.5 system often had a small change made to vdb_rate.cpp, allowing integration to continue even when a point was not fresh, using its last good rate value. This allows calculated volume integrations to match more closely with what oth...
Jake Hawkes almost 5 years ago in Enterprise SCADA Server / Krunch and Data Manipulation 0 Future consideration

Alarm should be generated when Omnicomm stops polling a connection record due to being added to the bad hosts list

Create an alarm when omnicomm detects DNS issues and puts a connection offscan.
Jake Hawkes over 2 years ago in Enterprise SCADA Server / Alarms / Omnicomm / Protocols and Commlines 1 Reviewing

OSM Improvement proposal - Enter the number of signatures on the signature tab

"User requested priority of P2 High Show the number of signatures (required / optional) on the signature tab (in the same way as one has on references). Can save the assets time. Comment from Per Sunde: The number of signatures should be shown on ...
Ashutosh Dubey over 3 years ago in Operational Safety Management / Work Permits 1 Already exists

OSM Improvement Proposal - Show all AT related to all operations on the work order

The suggestion is that when you are in eg: PM03-300166549. then all WP's related to PM03-300166549-0010 and PM03-300166549-0020 and PM03-300166549-0030 are also displayed on it. that these are not hidden during the operations
Ashutosh Dubey over 3 years ago in Operational Safety Management / Work Permits 1 Already exists

OSM Improvement proposal - Wish to get a list of all subtypes that have been ticked off on the AT

"If you have an WP that has first choice for e.g. Hot work at B and you add work over sea, you will not get work over sea in the subtype column (see attached image). You will also not get this AT if you apply on work over seas. Wish that all the s...
Ashutosh Dubey over 3 years ago in Operational Safety Management / Work Permits 1 Already exists