To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

BACNET: Addressing objects via ObjectName

We have several requests for accessing BACNET objects via their "ObjectName", rather than their HW address ie: AI.1.PresentValue. There are 2 issues with the current way of addressing: Makes it difficult to make equipment Some PLC’s (ie Wago) shif...
Guest over 6 years ago in Device Integration 1

New System Tag to receive external commands to Reset the connection on specific devices

Adding an external PLC channel reset System Tag feature would significantly improve operational reliability. This capability is particularly important in scenarios such as PLC reboots, communication interruptions, or network-related outages, where...
Marcel Lima 9 months ago in Device Integration 0

S7TCP support for firmware V3.0 with username and password

To increase security this option is available on the S7-1500 controller. Without a username and password anyone connected to the network can connect, browse and change values.
Guest over 2 years ago in Device Integration 4 Planned

Modifications to Persistent Memory Device without downtime

Structural changes to Persisted Memory tags (such as modifying the array size) cannot be applied while any I/O server hosting that device is still running. A brief coordinated stop of all I/O servers is the required procedure. When an I/O server s...
Guest 5 months ago in Plant SCADA / Drivers / Protocols 0 Submitted

Invalid Timestamp Handling in IEC 60870-5-104 Driver within AVEVA Telemetry Server

In an energy remote control system, we are using the AVEVA Telemetry Server to read/write data from PLCs via the IEC 60870-5-104 protocol. During analysis of the communication frames, we have observed that, in some cases, values are received with ...
Jordi Román about 1 year ago in Device Integration 0

OPCUA Variable Import limited to 79 characters

When you import Variable Tags from an OPCUA Server the tag names are truncated to 79 characters, this is sometime not enough. Duplicate tagnames are not allowed. You have to manually adjust all the names. For instance when you connect to a Plant S...
Guest about 3 years ago in Plant SCADA / Drivers / Protocols 2 Reviewed & Categorized

MQTT

More and more devices support MQTT protocol
Ales B over 6 years ago in Device Integration 5

BTL listing of Bacnet driver

We are getting a lot of feedback in the market about us not being BTL listed as a compliant B-AWS/ B-OWS. We see this being demanded in more and more tenders, so I was wondering if this is something you have looked at. The basic stuff for B-OWS se...
Guest about 6 years ago in Device Integration 1 Will not implement

Modify the S7TCP driver to support S7 PLCSIM Advanced

Modify the S7TCP driver to support S7 PLCSIM Advanced
Peter Holmberg almost 2 years ago in Plant SCADA / Drivers / Protocols 0 Submitted

wwClient update/fix

Hi everybody, for convenient troubleshooting of SuiteLink communication with drivers, it would be useful to have an upgraded version of the wwClient utility, which right now doesn't support encrypted SL (making it useless many times in SMS environ...
Mattia Popolla about 1 year ago in Device Integration 1 Will not implement