To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 28 of 791

Analog field rawval should be replicated to non-owning sites

Client has observed that the ANALOG "rawval" field is not replicating to non-owning sites; and they expect this value to be replicated. Anything else relevant to this feature? There is an optional feature called the "Raw Data Enhancement" RAW_ENAB...
Guest about 2 years ago in Enterprise SCADA Server / Replication 2 Waiting for information

Improvements to OPC Client

Enhance the OPC Client such that it can handle third-party OPC Servers that present 10,000+ points as one remote. This "idea" relates to GCS ticket # 960321526.
Craig Parkin about 2 years ago in Enterprise SCADA Server / Protocols and Commlines 1 Waiting for information

ADE find/replace case sensitivity

Summary In 7.6, the Find was insensitive but the Replace was sensitive. This resulted in fewer rows being modified than what was found in the Find. In other words, it was a hidden defect. Making Find and Replace consistent was important to ensure ...
Josie Liu over 2 years ago in Enterprise SCADA Server / ADE / PnT / MoC 2 Will not implement

IEC-104

IEC60870-101 or IEC60870-104 are the serial and IP versions of what is sometimes refered to IEC-104. These are both part of the IEC60870-5 standard, whereas ICCP is IEC60870-6, and is different. IEC_62351 is a standard for securing the various pro...
Josie Liu almost 6 years ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines / Telemetry 0 Reviewing

ADE permit to use symbols (),.-/

On ADE, Address1 and Address2 fields in the Station table of ADE do not permit the use of symbols such as (),.-/, even though these characters can be part of legitimate addresses.
Gerald Tseng over 1 year ago in Enterprise SCADA Server / ADE / PnT / MoC 0

Allow protocol specific extensibility of dnlist ADE Form

The dnlist ADE form has protocol specifics built in for BSAP and Fisher ROC but does not allow any extensibility so it is difficult to add "Download by List" functionality to a new protocol (such as DNP3).
Collin Heggerud over 1 year ago in Enterprise SCADA Server / ADE / PnT / MoC / Protocols and Commlines / Telemetry 1 Will not implement

Testing as a Service

Multiple customers have offered to share their test scripts with us to improve our ability to test usage that better matches customer environments.

Collect doesn't collect current real-time value at top of hour

Customer Requirement Our customers require the ability to maintain complete Timeseries historical trends (collect samples), including timestamped samples polled after a PLC communication loss (outage could be for several hours/days). The customer ...
Guest almost 4 years ago in Enterprise SCADA Server / Historical / Realtime 2 Waiting for information

Expansion of point description field string length

SE PA WWW previously modified database schema and structure now with binary release modifications tot he database structure are limited. Support for modifying existing types including changing string length is not supported. SE PA WWW typically...
Guest almost 4 years ago in Enterprise SCADA Server / Realtime Schema 3 Will not implement

NMC should not log confusing messages if the ADLDS Cross Domain Replication sender is also a receiver from another ADLDS realm

The current 2023 system designs being provided to customers include an es/deployment system with it's own ADLDS realm. AOR area/group changes are made there first and it is the global table owner for its realm. The primary production system is set...
Hugh Arai about 2 years ago in Enterprise SCADA Server / Administration / Installation / Replication 0 Reviewing