To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 44 of 776

Multi-system support for HMI

User Story As a pipeline operator / supervisor monitoring pipeline assets that span multiple RealTime environments, I would like to be able to connect my HMI to the combined multi-RealTime environment, conferring all benefit of functionality co...
Tyson Burr over 4 years ago in Enterprise SCADA Server / Architecture / Control Room Management 1 Future consideration

Disable read from certain tags in knx driver

The driver will today read everything after a certain time if not otherwise refreshed. Some tags are not readable and event based only, to avoid uneccesary traffic there should be a possibility to disable read, similar to option for setpoints.
Dan Helgeland over 2 years ago in Device Integration 0

Enhance Device Rollup to support subdevices from multiple datasets

Big Picture User Experience Enhance device rollup from subdevices (telemetered and device object) that belong to datasets that differ from the parent device (top-level device) object dataset. Background With large systems it is now very common to ...
Guest over 2 years ago in Enterprise SCADA Server / Alarms / Control Room Management 0 Reviewing

User alarm limits should obey existing alarm deadbanding configuration

After configuring user alarms using the “user hi” and “user lo” functionality, alarms are being generated without consideration for the alarm level deadband configured for the point. For example: A user high alarm configured at 100 will ring into ...
Guest over 2 years ago in Enterprise SCADA Server / Alarms 0 Reviewing

Multiple transient state support for multistate command

Detailed Description Due to various physical factors, sometimes a 2-bit status point will transition through both the (valid) TRANSIT state as well as the (invalid) ERROR state, on its way from CLOSED to OPEN (or vice versa). This enhancement will...
Guest over 2 years ago in Enterprise SCADA Server / Alarms / Krunch and Data Manipulation 0 Reviewing

DNP3 - "Listening mode"

The current version of DNPR or DNP3 driver always want's to initiate the start of communication with the device. There are some devices that work in an opposite direction (i.e. Metasphere DNP3 data loggers https://www.metasphere.co.uk/products/poi...
Ales B over 5 years ago in Device Integration 0

Citect OPCUA Client Driver - Configuring Subscription Sampling Interval to something other than double the subscription rate.

As mentioned in OPC UA driver help (OPCUA Driver > Advanced Configuration and Maintenance > Subscription Management) : "The driver sets the OPC UA subscription sampling interval equal to be half of the publishing interval." Means setting the...
Guest over 3 years ago in Device Integration 1

Ability to add new fields to almsum/event tables in ES2021

One of our water projects will be upgrading to 2021 (or 2022) from 7.5. They've previously customized their almsum and event tables to include an additional field (a record name from a custom table). I know that we can add fields to Realtime table...
Natalie Hunter almost 4 years ago in Enterprise SCADA Server / Alarms / Realtime Schema 2 Waiting for information

Capture the desired precision for analogs in the backend for use by the HMI

Big Picture User Experience Customers desire to configure the number of decimal places used when displaying floating point numbers on the alarm summary only. Detailed Description The current workaround is to use the internationalisation feature to...
Jake Hawkes almost 5 years ago in Enterprise SCADA Server / Control Room Management 1 Will not implement

Ability to filter out parked alarms from alarm summary screen

Big Picture User Experience TransGas would like to have the ability to hide parked alarms from the alarm summary display. They use alarm parking extensively and feel that having the parked alarms shown on the display makes it more difficult for th...