To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Enhance Re-alarming application for any alarm severity

Big Picture User Experience Enable Re-Alarming application to re-alarm alarms of any severity that were acknowledged by SCADA controller Detailed Description Background Re-Alarming application designed to re-annunciate alarms that are previously w...
Guest over 3 years ago in Enterprise SCADA Server / Alarms 1 Future consideration

MQTT Last Will Message

As of current state, the publishers that do not use Sparkplug B and rely on vanilla JSON format do not get benefit of Data Quality change for tags where a Last Will Message has been received by the Subscriber. A simple fix to implement is the abil...
Lakshay Mundeja almost 2 years ago in Device Integration 0 Planned

Mitsubishi FX5U PLC driver for Plant SCADA

MELSECQ protocol can be used to communicate with FX5U, but the addressing system is different. MELSECQ expects Hexadecimal addressing while FX5U expects Octal addressing system.
Jiri Rysavik about 2 years ago in Device Integration 0

How to communicate between Plant SCADA and OMRON PLC NJ series

Among Korean Plant SCADA users, there are often users who use Omron NJ series PLC. They express great inconvenience and dissatisfaction about the lack of communication between Plant SCADA and Omron NJ PLC. The method of changing the address of KB0...
Guest about 2 years ago in Device Integration 0

Allow customers to latch alarms

Here is one problem customers are encountering with our alarming philosophy, where we replace the existing alarm with a new one with the current alarm state: Because the alarm for exceeding hi-hi isn’t latched, operators are missing that MAOP was ...
Collin Heggerud over 6 years ago in Enterprise SCADA Server / Alarms / Control Room Management 0

S7TCP driver issue addressing arrays

Currently the S7TCP driver reads individual element of an array. Need functionality to read array as a whole
Guest over 2 years ago in Device Integration 1

Add "Inhibit" column to baseline Point Event Summary display

Current baseline Event Summary display has a column called Inhibit which indicates the type of alarm inhibit. See attachment Event_Summary.png. On the other hand, the current baseline Point Event Summary display doesn't have that column. See attac...
Guest over 2 years ago in Enterprise SCADA Server / Control Room Management 1 Reviewing

Parent control alarm suppression for ROC alarms

The Chevron 2022 SP1 project is requesting the ability to use Parent control alarm suppression to suppress ROC alarms
Hugh Arai over 2 years ago in Enterprise SCADA Server / Alarms 0

Multi-system support for HMI

User Story As a pipeline operator / supervisor monitoring pipeline assets that span multiple RealTime environments, I would like to be able to connect my HMI to the combined multi-RealTime environment, conferring all benefit of functionality co...
Tyson Burr over 5 years ago in Enterprise SCADA Server / Architecture / Control Room Management 1 Future consideration

DNP3 - "Listening mode"

The current version of DNPR or DNP3 driver always want's to initiate the start of communication with the device. There are some devices that work in an opposite direction (i.e. Metasphere DNP3 data loggers https://www.metasphere.co.uk/products/poi...
Ales B over 6 years ago in Device Integration 0