Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 31 of 791

Parent control alarm suppression for ROC alarms

The Chevron 2022 SP1 project is requesting the ability to use Parent control alarm suppression to suppress ROC alarms
Hugh Arai almost 2 years ago in Enterprise SCADA Server / Alarms 0

Allow customers to latch alarms

Here is one problem customers are encountering with our alarming philosophy, where we replace the existing alarm with a new one with the current alarm state: Because the alarm for exceeding hi-hi isn’t latched, operators are missing that MAOP was ...
Collin Heggerud almost 6 years ago in Enterprise SCADA Server / Alarms / Control Room Management 0

Create lots and lot groups with surveys

Currently only a movement in/out of a lot/lotgroup will create a new lot/lotgroup. However there are many scenarios when a new lot/lotgroup will be introduced into the system using a survey event.BHP Chile has this scenario when start blasting a n...
Mehrnoosh KHODAVERDY over 4 years ago in Production Management (AMPLA MES) / Inventory 1 Future consideration

Multi-system support for HMI

User Story As a pipeline operator / supervisor monitoring pipeline assets that span multiple RealTime environments, I would like to be able to connect my HMI to the combined multi-RealTime environment, conferring all benefit of functionality co...
Tyson Burr over 4 years ago in Enterprise SCADA Server / Architecture / Control Room Management 1 Future consideration

Enhance Device Rollup to support subdevices from multiple datasets

Big Picture User Experience Enhance device rollup from subdevices (telemetered and device object) that belong to datasets that differ from the parent device (top-level device) object dataset. Background With large systems it is now very common to ...
Guest over 2 years ago in Enterprise SCADA Server / Alarms / Control Room Management 0 Reviewing

User alarm limits should obey existing alarm deadbanding configuration

After configuring user alarms using the “user hi” and “user lo” functionality, alarms are being generated without consideration for the alarm level deadband configured for the point. For example: A user high alarm configured at 100 will ring into ...
Guest over 2 years ago in Enterprise SCADA Server / Alarms 0 Reviewing

Multiple transient state support for multistate command

Detailed Description Due to various physical factors, sometimes a 2-bit status point will transition through both the (valid) TRANSIT state as well as the (invalid) ERROR state, on its way from CLOSED to OPEN (or vice versa). This enhancement will...
Guest over 2 years ago in Enterprise SCADA Server / Alarms / Krunch and Data Manipulation 2 Reviewing

Evaluated fields for Material movement items

Material movement items currently do not support evaluated fields. As a part of the Alcoa project, at a certain point in their design, which uses meter marks to capture movements, having evaluated fields on movements would have helped to work out ...
Priyanka VINAYCHANDER over 6 years ago in Production Management (AMPLA MES) / Configuration / Inventory 0 Future consideration

Ability to add new fields to almsum/event tables in ES2021

One of our water projects will be upgrading to 2021 (or 2022) from 7.5. They've previously customized their almsum and event tables to include an additional field (a record name from a custom table). I know that we can add fields to Realtime table...
Natalie Hunter almost 4 years ago in Enterprise SCADA Server / Alarms / Realtime Schema 2 Waiting for information

Add evaluated fields for movements

There is different scenarios when an evaluated fields required on a movement. For example when you have online analyzers which give you the estimated grade or moisture and you would like to be able to have the dry tonnes or fine material in the mo...
Mehrnoosh KHODAVERDY over 4 years ago in Production Management (AMPLA MES) / Inventory 1 Future consideration