Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Configure a commanded status point to alarm in abnormal state

Customer desires the ability to configure status points so that an alarm is generated when a status point is commanded to (and enters) an abnormal state. Attaching use case as described by customer in SC 960445947
Guest almost 2 years ago in Enterprise SCADA Server 1

Enhance NMC to be more descriptive as to what resource the "FreeSpace" monitoring/alarm is for

Has this functionality been delivered before?: It is configurable today, but must be done on every machine individually. In large installs, this is a large effort. Links OGPM: http://tcjira.aveva.com/browse/OGPM-3091
Tyson Burr almost 3 years ago in Enterprise SCADA Server / Administration / Installation / Architecture 0 Future consideration

Point Conditioning application should support point conditioning updates from multi threaded callers

[customer] experienced lock contention issues when updating point conditioning inputs from within ACE code. Investigation into this issue in support case https://gcsservicecloudutils.azurewebsites.net/casedetails?casenumber=960273706 and R&D I...
Andrew Potkins over 1 year ago in Enterprise SCADA Server / Realtime 0

Safety Points support for Connection/Remote records

Enbridge control room operators have requested that the safety points feature, currently available for telemetry points, to be extended to the connection and remote tables. The intent is to allow communication alarms to be flagged, for PLC or site...
Guest about 2 years ago in Enterprise SCADA Server / Alarms 2 Reviewing

Add ability to delete lot group reporting point record from PA

Currently, we can delete the Lot group reporting point record in the lot group standard view from the table LotGroupDataSet by using the Delete Script. There is no option to delete the record from the Production analyst in Inventory. Can you pleas...
Nina NICHOLLS over 1 year ago in Production Management (AMPLA MES) / Production Analyst 0 Needs review

SPS version 11 support for RTUPlayer and Trainer.

Requesting support for SPS 11.1 and Windows Server 2022 operating system for RTU Player and Trainer applications.
Andrew Potkins 10 months ago in Enterprise SCADA Server / Applications 0

Allow the "safety string" to be moved or disabled in the alarm message

Currently in baseline, (SAFETY) is always added as a prefix to Safety Related alarm messages. It is used as the marker whether the alarm should be recorded in the event table as safety-related. Our customer wants to have (SAFETY) as a suffix for t...
Hugh Arai 10 months ago in Enterprise SCADA Server / Alarms 0

Omnicomm should better support modern network speeds

Omnicomm has a feature that allows it to wait longer for large messages than for short messages. This feature defaults to calculations based on messages transmitted at 1200bps and has a maximum configurable rate of 38400bps. In a world where many ...
Collin Heggerud 10 months ago in Enterprise SCADA Server / Omnicomm 0

Omnicomm retries on temporary connections should retry the connection

On Tech Support case 962469169 it became very clear that when the socket of a temporary connection was broken, Omnicomm would not re-attempt the connection until the next scheduled poll interval (e.g., 5 minutes later). I would expect that if Omni...
Collin Heggerud 10 months ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines 0

Point to Point Verfication to support multiple systems

Point to Ppoint Verification application should be to work in an enviroment where mulpltle systems are owning datasets.
Vitali Unke 11 months ago in Enterprise SCADA Server 0