To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 776 of 776

Add 64-bit INT to Modbus Driver

Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Guest over 2 years ago in Plant SCADA / Drivers / Protocols 1

SPS version 11 support for RTUPlayer and Trainer.

Requesting support for SPS 11.1 and Windows Server 2022 operating system for RTU Player and Trainer applications.
Andrew Potkins 2 months ago in Enterprise SCADA Server / Applications 0

Windows should have icons to indicate presence of scripts

I often need to migrate older InTouch applications to the latest version. Every time, the applications have scripting, but also window scripts and action scripts (buttons for example). It would save a lot of time if the UI would indicate what wind...
Rares Plesea about 1 year ago in InTouch HMI 0

Secured and Verify Writes popup for boolean shoud show Onmsg/Offmsg instead of True/False

The popup for secured/verify writes is showing the value True or False. Would be more logical that it uses the OnMsg or OffMsg that is configured for the corresponding attribute.
Lauran Lint 11 months ago in Application Server / Security 0

Mention in the manual the default History store forward directory

Application Server Platform and Engine object General tab. On a regular base customers are asking what the store and forward directory location is when leaving the configuration empty. This isn't mentioned in the manual. If you use the configurati...
Lauran Lint 4 months ago in Application Server / Documentation 0

New portal to download Industrial Graphics

AVEVA should create a new web portal where they, as well as other parties, can upload and share IG Libraries to be used in AVEVA solutions. AVEVA could even implement a payment system to allow itself and other graphics creators to get payed per do...
Rares Plesea 4 months ago in Application Server / Industrial Graphics 0

Dark Element Styles for Industrial Graphics

I wish AVEVA to ship dark styles for Industrial Graphics (OMI. InTouch, Edge, Plant). At least one style, though would be great if all existing styles (grey, brick, olive etc) would get a dark variant.
Rares Plesea 4 months ago in Application Server / Industrial Graphics 0

OS-Configuration Utility needs an option to not overwrite existing Firewall rules during upgrades.

We are using System Platform 2023----After our normal installation and hardening, we have 22 firewall rules on the system. After installing the SP, (with OS-Configuration Utility) we suddenly have 245 rules. See attachment for details. Requirement...
Guest 11 months ago in Application Server / Configuration / Installation / Security 1

Reading 64-Bit Double (Float) in OPC UA as a String

Energy meters and sensors often are using IEEE double precision (64 bit) floating point datatypes for counters and totalizer. Reading this Items as a string from the OPC server and then convert it in a Real Data type Cicode Variable can allow us ...
Guest over 5 years ago in Device Integration 2

Allow the "safety string" to be moved or disabled in the alarm message

Currently in baseline, (SAFETY) is always added as a prefix to Safety Related alarm messages. It is used as the marker whether the alarm should be recorded in the event table as safety-related. Our customer wants to have (SAFETY) as a suffix for t...
Hugh Arai 2 months ago in Enterprise SCADA Server / Alarms 0