Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

When Selecting More than one Object to Deploy, Deploy all contained objects underneath them.

If you select one object to deploy and it has contained objects those objects will be deployed. If you select multiple objects using Shift or Control only those objects are deployed and not the contained objects underneath them.
Jeff Scheer over 1 year ago in Application Server / IDE 0

Faster compiler

The old compiler needs to utilize modern hardware better to decrease compile-time. Also applies to other tools who I suspect uses same/similar routines working with DBFs and such. Like page update and packing, etc.
Guest about 3 years ago in Plant SCADA / Development Tools 0 Future Consideration

wwClient update/fix

Hi everybody, for convenient troubleshooting of SuiteLink communication with drivers, it would be useful to have an upgraded version of the wwClient utility, which right now doesn't support encrypted SL (making it useless many times in SMS environ...
Mattia Popolla 10 months ago in Device Integration 1 Will not implement

Support multiple cores for InTouch

Introduce support for distributing the processing load across multiple cores for InTouch for better utilization of resources and performance.
Mohammad Azhar about 2 years ago in InTouch HMI 0 Planned

Native UMAS driver for Modicon PACs

Word is out that active OFS development has stopped. OFS is the current high-performance driver for all Schneider Electric / Modicon PLCs, using its proprietary UMAS protocol. Communication using UMAS and OFS has many advantages over standard Modb...
Guest over 1 year ago in Plant SCADA / Drivers / Protocols 0 Unlikely to implement

Equipment editor use patterns

When creating Equipment types it will save a lot of time when it is possible to use pattern’sFor example when creating an alarm several Item’s need to be created with the same structure: <alarm>_Suppression <alarm>_Condition <alarm&...
Guest over 3 years ago in Plant SCADA / Equipment 3 Future Consideration

Act as a REST/ WEB API server

Act as a REST API Server like the GR Access Tool for better integration with other products. GR Access Toolkit SDK needs to be written in .NET where REST API supports multiple programming languages.
Rainer Dsouza about 1 year ago in Application Server / Device Integration 1

Edit Equipment types with a table tool like Excel

when it is needed to update a lot (not all) of variable and trend definitions for example Historian = true within an equipment type. Browsing to the item, opening the definition, add the field and set the value to true will take a lot of time. Whe...
Guest over 3 years ago in Plant SCADA / Equipment 3 Unlikely to implement

Remove Engine Option

Kill Platform is a good utility that is available to remove Platform if its stuck in deployment/undeployment however nothing like that exists for engine. But most of the times, the platform i& other engines are working fine. A utility to remov...
Lakshay Mundeja over 1 year ago in Application Server / Application Server Runtime 2

Enlarge the tables in the kernel

For instance the CSAToPSI.Subs, it starts with the cluster name, then the tag, which can 79 characters. You can only see 29 characters. Also in a kernel dump the length is limited. Also sorting on different colums would be helpfull.
Guest over 3 years ago in Plant SCADA / Kernel & Diagnostics 0 Reviewed & Categorized