Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

be able to modify the “buffered” property of an I/O in derived templates that inherit I/O attributes

at the moment when a template that already has an I/O attribute is derived, the 'Buffered' property of the attribute (located under I/O->Advanced) is inherited (regardless of the locks) and cannot be modified, you are forced to decide this prop...
Giuseppe Acampora 11 months ago in Application Server / Development 0

EmbedContent () function does not open all graphics correctly

EmbedContent () function does not open all graphics correctly - object wizard options and choices that are linked to symbol wizard options and choices are not taken into account by the EmbedContent () function. Additional information is in: SR: 96...
Guntars Rubenins about 1 year ago in Application Server / OMI desktop runtime 1

can change Height on Combobox

on graphic can change Height on Combobox
Jean-François POULAIN almost 2 years ago in Application Server / Visualization 0

Multi-object properties editing

Ability to modify multiple common properties across several templates at once (e.g., unit of measure, writability, I/O scaling, etc.)
Luca Preziosa about 1 year ago in Application Server / Configuration 1

Custom Namespaces values in Object Viewer

Enable the ability to view the runtime values of Custom and Standard Namespaces in the Object Viewer.
Luca Preziosa about 1 year ago in Application Server / Diagnostics 1

Add 64-bit INT to Modbus Driver

Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Guest almost 3 years ago in Plant SCADA / Drivers / Protocols 1 Reviewed & Categorized

Include the Tank functionality in the baseline portion of the product

The Tank table is tied to the LMS apps and does not get exposed on a baseline system where some customers could benefit from its built in nature. Allowing a customer to use the Tank table (and the new FlexTank object) as opposed to a custom reserv...
Guest 8 months ago in Enterprise SCADA Server / Applications 1

Ability to choose timezone of dates and times in UI

When investigating something like an anomaly score for a plant located in a different timezone than the user, it can be confusing to try to line up anomaly spikes with what is happening in the plant. It would be nice to be able to configure a diff...
Jessica Rammo over 1 year ago in Advanced Analytics 0 Needs review

Object Performance Index

Helping users understand the resource requirements Most aspects of perfromance is dependent on the object's complexity, but there is no good way to measure that complexity. This is also required to help with the queuing mechanism described above, ...
Ernst Van Wyk almost 2 years ago in Application Server / Application Server Runtime / IDE 0 Planned

Improve the warning/alarm message of the Admin Pager for low Physical Memory threshold

The default wmimonitor alarm message reports "freespace" is below warning\alarm limit for both low physical memory and logical disk. Requesting the messages are updated to be more clear which resource is affected by changing the physical memory me...
Vitali Unke 9 months ago in Enterprise SCADA Server / Alarms 0